Araştırma Çıktıları

Permanent URI for this communityhttps://hdl.handle.net/11443/931

Browse

Search Results

Now showing 1 - 2 of 2
  • Thumbnail Image
    Item
    Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study
    (TURKISH ASSOC ORTHOPAEDICS TRAUMATOLOGY, 2016-01-01) Sariyilmaz, Kerim; Korkmaz, Murat; Ozkunt, Okan; Gemalmaz, Hall Can; Sunguill, Mustafa; Baydogan, Murat; Kaya, Ibrahim; Okla, Fatih
    Objective: The purpose of this study was to biomechanically compare cable, trochanteric grip plate, and locking plate techniques in Vancouver type AG fracture model in an in vitro test environment. Methods: Fifteen pieces of fourth-generation synthetic femora were separated into 3 groups of 5 models each. A greater trochanteric fracture model was created after femoral stem implantation. Group 1 was fixated with only cable, Group 2 with trochanteric grip plate, and Group 3 with locking plate. Horizontal stiffness, axial stiffness, and failure loads were compared between the groups. Results: In horizontal compression tests, Group 3 had the highest values, but the only statistically significant difference was between the locking plate group and cable group. Axial distraction test results showed that mean stiffness of Group 1 was 94.6 +/- 9.44 N/mm, that of Group 2 was 174.8 +/- 28.64 N/mm, and that of Group 3 was 185.6 +/- 71.64 N/mm. While locking plate versus cable fixation and grip plate fixation versus cable fixation showed statistically significant differences (p<0.05), comparison of locking plate versus grip plate fixation showed no statistically significant difference (p>0.05). In axial failure load test, Group 3 had the highest results. The only significant difference was between the locking plate and cable groups (p<0.05). Conclusion: In Vancouver type AG fractures stable fixation may be achieved with grip plate fixation and locking plates, with the former ensuring more stable osteosynthesis.
  • Thumbnail Image
    Item
    The effect of onlay cortical fibula strut grafts on biomechanical features of Vancouver type B1 periprosthetic femoral fractures
    (TURKISH ASSOC ORTHOPAEDICS TRAUMATOLOGY, 2022-01-01) Aliyev, Orkhan; Erden, Tunay; Sariyilmaz, Kerim; Bozdag, Ergun; Sunbuloglu, Emin; Tuncay, Ibrahim; Yildiz, Fatih
    Objective: This study aimed to investigate biomechanically the effects of onlay fibula grafts on Vancouver Type B1 Periprosthetic Femoral Fractures (PPFs). Methods: Vancouver Type B1 PFF models were created in 25 fourth-generation synthetic femurs and fixed with locking plates using bicortical, unicortical screws, and cables. While no graft was used in group 1, onlay fibula grafts were placed anteriorly in group 2 and medially in group 3. In group 4, the cortical strut allograft was placed on the medial femoral cortex, and a locking compression plate (LCP) was applied to the lateral femoral cortex. In group 5, the strut allograft was placed over the anterior cortex of the femur and fixed with the same technique as in group 4. All models were then subjected to rotational and axial cyclical stiffness tests and load to failure to measure and compare the mechanical strengths of the constructs. Results: The mean stiffness values of group 4 with medial allograft, before and after cyclical loading, were higher than all other groups, under both rotational and axial forces. The mean stiffness values of fibula autografts (groups 2 and 3) were similar to that of anterior allografts (group 5) in each test except that the mean initial axial stiffness of group 5 was higher than group 2. Failure loads were also not different between the groups. Conclusion: Although the rigidity of Vancouver type B1 periprosthetic femur fractures is highest if allografts are placed medially, fibula autografts can also provide similar fixation strengths to allografts if locking plates with unicortical and bicortical screws and cables are used.