Closed-loop synchronization versus conventional synchronization in spontaneously breathing pediatric patients (CHESTSIPP) - a randomized controlled cross-over study
| dc.contributor.author | Ceylan, Gokhan | |
| dc.contributor.author | Sarac, Ozlem | |
| dc.contributor.author | Atakul, Gulhan | |
| dc.contributor.author | Soydan, Ekin | |
| dc.contributor.author | Colak, Mustafa | |
| dc.contributor.author | Topal, Sevgi | |
| dc.contributor.author | Hepduman, Pinar | |
| dc.contributor.author | Novotni, Dominik | |
| dc.contributor.author | Meyer, Johannes | |
| dc.contributor.author | Karaaslan, Utku | |
| dc.contributor.author | Revely, Jean-Pierre | |
| dc.contributor.author | Agin, Hasan | |
| dc.date.accessioned | 2026-11-05T11:06:33Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Background: Patient-ventilator asynchrony (PVA) is common during invasive mechanical ventilation in children and may increase respiratory workload and discomfort. The IntelliSync+ (IS+) algorithm provides closed-loop synchronization by continuously analyzing airway pressure and flow waveforms to optimize inspiratory and expiratory cycling in real time. This study evaluated the efficacy and safety of IS+ compared with conventional physician-tailored synchronization in spontaneously breathing pediatric patients. Methods: Multicenter, prospective, randomized controlled, single-blind crossover trial conducted in four pediatric intensive care units between March 2024 and May 2025. Patients aged 1 month to 18 years undergoing invasive mechanical ventilation were randomized to begin with either IS+ or conventional synchronization. Each mode was applied for 90 min (30-min run-in and 60-min measurement), separated by a 30-min washout period. The primary outcome was the Asynchrony Index (AI). Secondary outcomes included major and minor asynchrony indices, Comfort-B scores, end-tidal carbon dioxide (EtCO2), oxygen saturation (SpO(2)), and leak percentage. Findings: Twenty-five patients completed both study phases. Compared with conventional synchronization, IS+ significantly reduced the overall AI (median 5.1% [IQR 4.2-6.4] vs. 12.4% [IQR 9.9-15.6]; P < 0.001), as well as both major and minor asynchrony indices (P < 0.001 for both). The frequencies of double triggering, auto-triggering, trigger delay, and early cycling decreased significantly, while ineffective efforts were unchanged and late cycling slightly increased. Comfort-B scores improved modestly (P = 0.02) and EtCO2 decreased (P < 0.001), whereas SpO(2) and leak remained stable. Conclusion: Closed-loop synchronization with IS+ significantly improved patient-ventilator interaction without compromising comfort, oxygenation, or safety. These results support closed-loop synchronization as a feasible and physiologically sound strategy for improving ventilatory support quality in pediatric invasive mechanical ventilation. | |
| dc.description.pages | 1745939 | |
| dc.description.sponsorship | The author(s) declared that financial support was not received for this work and/or its publication. | |
| dc.description.volume | 13 | |
| dc.identifier.doi | 10.3389/fmed.2026.1745939 | |
| dc.identifier.issn | 2296-858X | |
| dc.identifier.uri | https://doi.org/10.3389/fmed.2026.1745939 | |
| dc.identifier.uri | https://openaccess.acibadem.edu.tr/handle/11443/11363 | |
| dc.identifier.wos | WOS:001735127200001 | |
| dc.language.iso | en | |
| dc.publisher | FRONTIERS MEDIA SA | |
| dc.relation.hasversion | 10.3389/fmed.2026.1745939 | |
| dc.relation.ispartof | FRONTIERS IN MEDICINE | |
| dc.subject | asynchronies | |
| dc.subject | closed-loop | |
| dc.subject | mechanical ventilation | |
| dc.subject | pediatric acute respiratory distress syndrome (PARDS) | |
| dc.subject | spontaneous breathing | |
| dc.subject | synchronization | |
| dc.subject | waveform analysis | |
| dc.subject | VENTILATOR ASYNCHRONY | |
| dc.subject | PRESSURE-SUPPORT | |
| dc.subject | VOLUME | |
| dc.subject | Medicine, General & Internal | |
| dc.subject | General & Internal Medicine | |
| dc.title | Closed-loop synchronization versus conventional synchronization in spontaneously breathing pediatric patients (CHESTSIPP) - a randomized controlled cross-over study | |
| dc.type | Article | |
| oaire.citation.edition | Science Citation Index Expanded (SCI-EXPANDED) | |
| oaire.citation.volume | 13 | |
| person.identifier.rid | AFW-8030-2022 | |
| person.identifier.rid | JAO-2810-2023 | |
| person.identifier.rid | JYQ-2668-2024 | |
| person.identifier.rid | JLL-9304-2023 | |
| person.identifier.rid | JDW-3813-2023 | |
| person.identifier.rid | AAG-3609-2021 | |
| person.identifier.rid | NHP-1194-2025 |