<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Intrapelvic Landmarks Are Highly Unreliable in Acetabular Cup Positioning Through Direct Anterior and Posterolateral Approaches: A Cadaveric Study

dc.contributor.authorYildiz, Fatih
dc.contributor.authorIncesoy, Mustafa Alper
dc.contributor.authorErdem, Ahmet Can
dc.contributor.authorDemirkiran, Cemil Burak
dc.contributor.authorOzdemir, Asena Ayca
dc.contributor.authorTuncay, Ibrahim
dc.date.accessioned2026-11-05T11:02:55Z
dc.date.issued2026
dc.description.abstractBackgroundAccurate acetabular cup placement is crucial for the long-term success of total hip arthroplasty (THA). This cadaveric study investigated the reliability of intrapelvic landmarks for cup positioning in conventional THA, examining the influence of surgeon experience, surgical approach (direct anterior and posterolateral), and pelvic positioning.Methods108 conventional THA procedures were performed on 24 hips of 12 lower extremity cadavers by nine surgeons with different surgical experiences (Group I: high volume, group II: intermediate volume and group III: low volume) through a posterolateral (PL) or direct anterior approach (DAA). The anteversion and inclination of the acetabular cups were measured using an image-based robotic arm system. Outliers were defined according to Lewinnek's and Callanan's safe zones and the groups were compared.ResultsIn groups I, II and III, the percentages of cups within the safe zone of Lewinnek for the combined versions were 38.9, 33.3, and 27.8 for DAA (p = 0.12); and 16.7, 27.8, and 16.7 for PL (p = 0.633) approaches, respectively, while the percentage of cups within the safe zone of Callanan for the combined versions was 27.8, 27.8, and 16.7 for DAA (p = 0.667); and 11.1, 16.7, and 11.1 for PL (p = 0.849) approaches, respectively.ConclusionThis study demonstrates the unreliability of intrapelvic landmarks for accurate acetabular cup placement in conventional THA, irrespective of surgeon experience. The absence of the trunk in the cadaveric model may have affected pelvic tilt, underscoring the importance of intraoperative pelvic positioning in achieving optimal cup placement. These findings suggest that reliance on intrapelvic landmarks alone may not be sufficient for accurate cup positioning and highlight the potential benefits of alternative techniques, such as robotic-assisted THA.
dc.description.issue6
dc.description.pages1450-1456
dc.description.sponsorshipThe cadavers utilized in this research were provided by Stryker.
dc.description.volume60
dc.identifier.doi10.1007/s43465-025-01638-5
dc.identifier.issn0019-5413
dc.identifier.issn1998-3727
dc.identifier.urihttps://doi.org/10.1007/s43465-025-01638-5
dc.identifier.urihttps://openaccess.acibadem.edu.tr/handle/11443/10987
dc.identifier.wosWOS:001629296000001
dc.language.isoen
dc.publisherSPRINGER HEIDELBERG
dc.relation.fundingStryker
dc.relation.hasversion10.1007/s43465-025-01638-5
dc.relation.ispartofINDIAN JOURNAL OF ORTHOPAEDICS
dc.subjectTotal hip arthroplasty (THA)
dc.subjectAcetabular cup accuracy
dc.subjectRobotic-assisted THA
dc.subjectSafe zone
dc.subjectSurgeon experience
dc.subjectCadaveric study
dc.subjectTOTAL HIP-ARTHROPLASTY
dc.subjectCOMPONENT
dc.subjectREPLACEMENT
dc.subjectORIENTATION
dc.subjectDISLOCATION
dc.subjectNAVIGATION
dc.subjectPLACEMENT
dc.subjectACCURACY
dc.subjectRISK
dc.subjectIMPINGEMENT
dc.subjectOrthopedics
dc.titleIntrapelvic Landmarks Are Highly Unreliable in Acetabular Cup Positioning Through Direct Anterior and Posterolateral Approaches: A Cadaveric Study
dc.typeArticle
oaire.citation.editionScience Citation Index Expanded (SCI-EXPANDED)
oaire.citation.endPage1456
oaire.citation.issue6
oaire.citation.startPage1450
oaire.citation.volume60
person.identifier.orcid0000-0001-5778-692X
person.identifier.orcid0000-0002-8552-0384
person.identifier.orcid0000-0002-0108-1880
person.identifier.orcid0000-0002-0275-8101
person.identifier.ridABA-2415-2020
person.identifier.ridIZP-9122-2023
person.identifier.ridKVA-7307-2024
person.identifier.ridGLV-2911-2022

Files

Collections