<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Mesoporous Hollow Carbon Nanospheres/Spiro Polymer-Based Immunosensors for Near-Field Communication (NFC)-Enabled Detection of Chronic Kidney Disease

dc.contributor.authorSoyler, Dilek
dc.contributor.authorTugay, Sema
dc.contributor.authorOz, Sena
dc.contributor.authorUcar, Ali Deniz
dc.contributor.authorKaya, Serdal
dc.contributor.authorCevher, Sevki Can
dc.contributor.authorOzufuklar, Ozge
dc.contributor.authorCelik, Emine Guler
dc.contributor.authorBulut, Umut
dc.contributor.authorUnalan, Husnu Emrah
dc.contributor.authorTimur, Suna
dc.contributor.authorSoylemez, Saniye
dc.date.accessioned2026-11-05T11:08:20Z
dc.date.issued2026
dc.description.abstractChronic kidney disease (CKD) poses a significant burden on healthcare systems due to its high treatment costs and elevated mortality rates, particularly in advanced stages. Early diagnosis and continuous monitoring are critical for improving patient outcomes and reducing healthcare expenditures. Herein, we report the development of a portable, rapid, and user-friendly electrochemical immunosensor for point-of-care (POC) applications, enabling early-stage detection and monitoring of CKD. The sensor was constructed using mesoporous hollow carbon nanospheres (MHCNSs) with an average diameter of 442 +/- 28 nm and a nanoscale shell thickness of approximately 25 nm, featuring nanoscale pores within the mesoporous shell, together with a spiro-based conjugated polymer (P-SFXAlFlu). Subsequently, biofunctional and selective recognition surfaces were fabricated by bioconjugation of specific antibodies of CKD biomarkers, kidney injury molecule-1 (KIM-1), and neutrophil gelatinase-associated lipocalin (NGAL), onto the polymer matrix. Then, the developed immunosensor was integrated with an NFC-based potentiostat, enabling wireless and portable detection of KIM-1 and NGAL for POC use. The biosensor platform was characterized using analytical techniques to assess its structure and electrochemical performance. The P-SFXAlFlu/MHCNSs/Anti-KIM-1 and P-SFXAlFlu/MHCNSs/Anti-NGAL immunosensors exhibited high sensitivity, stability, and selectivity. The sensors displayed a broad detection range of 10-150 ng/mL for KIM-1 and 20-200 ng/mL for NGAL, with low limits of detection (LOD) of 3.09 and 13.02 ng/mL, respectively. Furthermore, excellent specificity toward target biomarkers was demonstrated. These findings highlight the potential of carbon-based electrochemical immunosensors as reliable, sensitive, and portable platforms for accurate and rapid CKD detection in clinical settings.
dc.description.issue23
dc.description.pages10963-10974
dc.description.sponsorshipThis work was funded by COST Action CA21165, European Cooperation in Science and Technology, TUBITAK, the Scientific and Technological Research Council of Turkiye, 123S187 fellowship. D.S. thanks TUBITAK-BIDEB for the 2211A- PhD Scholarship Programs. S.T. thanks TUBITAK-BIDEB for the 2210C- Master's Scholarship Programs. S.S. acknowledges the financial support provided by the BAGEP Award of the Science Academy. S.S. and S.T. would like to thank Silicon Craft Technology for kindly gifting the NFC potentiostat used in this work.
dc.description.volume9
dc.identifier.doi10.1021/acsanm.6c01365
dc.identifier.issn2574-0970
dc.identifier.urihttps://doi.org/10.1021/acsanm.6c01365
dc.identifier.urihttps://openaccess.acibadem.edu.tr/handle/11443/11528
dc.identifier.wosWOS:001776319300001
dc.language.isoen
dc.publisherAMER CHEMICAL SOC
dc.relation.fundingT?rkiye Bilimsel ve Teknolojik Arastirma Kurumu
dc.relation.fundingEuropean Cooperation in Science and Technology(European Cooperation in Science and Technology (COST))
dc.relation.fundingBilim Akademisi
dc.relation.fundingT?rkiye Bilimsel ve Teknolojik Arastirma Kurumu [123S187]
dc.relation.fundingEuropean Cooperation in Science and Technology [CA21165]
dc.relation.fundingBilim Akademisi [Bilim Akademisi]
dc.relation.hasversion10.1021/acsanm.6c01365
dc.relation.ispartofACS APPLIED NANO MATERIALS
dc.subjectconjugated polymer
dc.subjecthollow carbon nanospheres
dc.subjectchronic kidney disease
dc.subjectimmunosensor
dc.subjectNFC
dc.subjectpoint-of-care test system
dc.subjectGELATINASE-ASSOCIATED LIPOCALIN
dc.subjectSPIRO
dc.subjectNanoscience & Nanotechnology
dc.subjectMaterials Science, Multidisciplinary
dc.subjectScience & Technology - Other Topics
dc.subjectMaterials Science
dc.titleMesoporous Hollow Carbon Nanospheres/Spiro Polymer-Based Immunosensors for Near-Field Communication (NFC)-Enabled Detection of Chronic Kidney Disease
dc.typeArticle
oaire.citation.editionScience Citation Index Expanded (SCI-EXPANDED)
oaire.citation.endPage10974
oaire.citation.issue23
oaire.citation.startPage10963
oaire.citation.volume9
person.identifier.orcid0000-0003-3667-179X
person.identifier.ridF-8392-2012
person.identifier.ridKCL-5870-2024
person.identifier.ridAAM-3317-2021
person.identifier.ridAAS-5799-2020
person.identifier.ridHZL-5399-2023
person.identifier.ridJQI-2061-2023
person.identifier.ridPIH-7110-2026
person.identifier.ridMWR-1846-2025
person.identifier.ridCAG-0914-2022
person.identifier.ridP-3609-2018

Files

Collections