<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

6-MINUTE PEGBOARD AND RING TEST IN PATIENTS WITH HEART FAILURE : AN ASSESSMENT OF VALIDITY, RELIABILITY AND MINIMAL DETECTABLE CHANGE

dc.contributor.authorEyolcu, Aylin Tanriverdi
dc.contributor.authorAcar, Serap
dc.contributor.authorOzsoy, Ismail
dc.contributor.authorKahraman, Buse Ozcan
dc.contributor.authorYilmaz, Mehmet Birhan
dc.contributor.authorOzpelit, Ebru
dc.contributor.authorAkdeniz, Bahri
dc.contributor.authorSavci, Sema
dc.date.accessioned2026-11-05T11:03:52Z
dc.date.issued2026
dc.description.abstractPurpose: Our study aimed to assess the validity, reliability, and minimal detectable change (MDC) of the 6-Minute Pegboard and Ring Test (6PBRT) in patients with heart failure (pwHF). Material and Methods: This cross-sectional study included 37 pwHF. Upper extremity functional capacity was evaluated using the 6PBRT. The 6PBRT was executed twice to investigate within-session reliability. The upper extremity muscle strength was measured using a dynamometer. Functional capacity, activities of daily living, and quality of life were assessed with the Milliken Activities of Daily Living Scale (MAS), six-minute walk test (6MWT) and Minnesota Living with Heart Failure Questionnaire (MLHFQ), respectively. Results: Reliability was excellent for 6PBRT, with an ICC of 0.957 (95% CI, 0.863 to 0.982). The MDC of the 6PBRT was 23.75 rings. The 6PBRT was strongly correlated with functional class (rho=-0.778, p<0.001), MAS (r=0.670, p<0.001) and 6MWT distance (r=0.626, p<0.001), and moderately correlated with age (r=-0.513, p=0.001), shoulder abductor (dominant r=0.580, p<0.001), shoulder flexor (dominant r=0.543, p=0.001), elbow extensor (dominant r=0.428, p=0.008), elbow flexor muscle strength (dominant rho=0.469, p=0.003), and MLHFQ (rho=-0.442, p=0.006). Conclusion: The 6PBRT provides a valid and reliable assessment of upper extremity functional capacity in pwHF. Executing 6PBRT at least twice is recommended to avoid the learning effect.
dc.description.issue1
dc.description.pages130-139
dc.description.volume10
dc.identifier.doi10.30621/jbachs.1826425
dc.identifier.issn2458-8938
dc.identifier.issn2564-7288
dc.identifier.urihttps://doi.org/10.30621/jbachs.1826425
dc.identifier.urihttps://openaccess.acibadem.edu.tr/handle/11443/11117
dc.identifier.wosWOS:001697507800016
dc.language.isoen
dc.publisherDOKUZ EYLUL UNIV INST HEALTH SCIENCES
dc.relation.hasversion10.30621/jbachs.1826425
dc.relation.ispartofJOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES
dc.subjectFunctional capacity
dc.subjectHeart failure
dc.subjectReliability
dc.subjectUpper extremity
dc.subjectValidity
dc.subjectUPPER-EXTREMITY
dc.subjectMILLIKEN ACTIVITIES
dc.subjectREFERENCE VALUES
dc.subjectSTRENGTH
dc.subjectADULTS
dc.subjectDETERMINANTS
dc.subjectGUIDELINES
dc.subjectAGREEMENT
dc.subjectCAPACITY
dc.subjectHealth Care Sciences & Services
dc.title6-MINUTE PEGBOARD AND RING TEST IN PATIENTS WITH HEART FAILURE : AN ASSESSMENT OF VALIDITY, RELIABILITY AND MINIMAL DETECTABLE CHANGE
dc.typeArticle
oaire.citation.editionEmerging Sources Citation Index (ESCI)
oaire.citation.endPage139
oaire.citation.issue1
oaire.citation.startPage130
oaire.citation.volume10
person.identifier.ridLTE-4312-2024
person.identifier.ridAAN-1568-2020
person.identifier.ridJAC-7345-2023
person.identifier.ridAFS-1649-2022
person.identifier.ridY-1372-2019
person.identifier.ridAAV-8016-2021

Files

Collections