6-MINUTE PEGBOARD AND RING TEST IN PATIENTS WITH HEART FAILURE : AN ASSESSMENT OF VALIDITY, RELIABILITY AND MINIMAL DETECTABLE CHANGE
| dc.contributor.author | Eyolcu, Aylin Tanriverdi | |
| dc.contributor.author | Acar, Serap | |
| dc.contributor.author | Ozsoy, Ismail | |
| dc.contributor.author | Kahraman, Buse Ozcan | |
| dc.contributor.author | Yilmaz, Mehmet Birhan | |
| dc.contributor.author | Ozpelit, Ebru | |
| dc.contributor.author | Akdeniz, Bahri | |
| dc.contributor.author | Savci, Sema | |
| dc.date.accessioned | 2026-11-05T11:03:52Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Purpose: Our study aimed to assess the validity, reliability, and minimal detectable change (MDC) of the 6-Minute Pegboard and Ring Test (6PBRT) in patients with heart failure (pwHF). Material and Methods: This cross-sectional study included 37 pwHF. Upper extremity functional capacity was evaluated using the 6PBRT. The 6PBRT was executed twice to investigate within-session reliability. The upper extremity muscle strength was measured using a dynamometer. Functional capacity, activities of daily living, and quality of life were assessed with the Milliken Activities of Daily Living Scale (MAS), six-minute walk test (6MWT) and Minnesota Living with Heart Failure Questionnaire (MLHFQ), respectively. Results: Reliability was excellent for 6PBRT, with an ICC of 0.957 (95% CI, 0.863 to 0.982). The MDC of the 6PBRT was 23.75 rings. The 6PBRT was strongly correlated with functional class (rho=-0.778, p<0.001), MAS (r=0.670, p<0.001) and 6MWT distance (r=0.626, p<0.001), and moderately correlated with age (r=-0.513, p=0.001), shoulder abductor (dominant r=0.580, p<0.001), shoulder flexor (dominant r=0.543, p=0.001), elbow extensor (dominant r=0.428, p=0.008), elbow flexor muscle strength (dominant rho=0.469, p=0.003), and MLHFQ (rho=-0.442, p=0.006). Conclusion: The 6PBRT provides a valid and reliable assessment of upper extremity functional capacity in pwHF. Executing 6PBRT at least twice is recommended to avoid the learning effect. | |
| dc.description.issue | 1 | |
| dc.description.pages | 130-139 | |
| dc.description.volume | 10 | |
| dc.identifier.doi | 10.30621/jbachs.1826425 | |
| dc.identifier.issn | 2458-8938 | |
| dc.identifier.issn | 2564-7288 | |
| dc.identifier.uri | https://doi.org/10.30621/jbachs.1826425 | |
| dc.identifier.uri | https://openaccess.acibadem.edu.tr/handle/11443/11117 | |
| dc.identifier.wos | WOS:001697507800016 | |
| dc.language.iso | en | |
| dc.publisher | DOKUZ EYLUL UNIV INST HEALTH SCIENCES | |
| dc.relation.hasversion | 10.30621/jbachs.1826425 | |
| dc.relation.ispartof | JOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES | |
| dc.subject | Functional capacity | |
| dc.subject | Heart failure | |
| dc.subject | Reliability | |
| dc.subject | Upper extremity | |
| dc.subject | Validity | |
| dc.subject | UPPER-EXTREMITY | |
| dc.subject | MILLIKEN ACTIVITIES | |
| dc.subject | REFERENCE VALUES | |
| dc.subject | STRENGTH | |
| dc.subject | ADULTS | |
| dc.subject | DETERMINANTS | |
| dc.subject | GUIDELINES | |
| dc.subject | AGREEMENT | |
| dc.subject | CAPACITY | |
| dc.subject | Health Care Sciences & Services | |
| dc.title | 6-MINUTE PEGBOARD AND RING TEST IN PATIENTS WITH HEART FAILURE : AN ASSESSMENT OF VALIDITY, RELIABILITY AND MINIMAL DETECTABLE CHANGE | |
| dc.type | Article | |
| oaire.citation.edition | Emerging Sources Citation Index (ESCI) | |
| oaire.citation.endPage | 139 | |
| oaire.citation.issue | 1 | |
| oaire.citation.startPage | 130 | |
| oaire.citation.volume | 10 | |
| person.identifier.rid | LTE-4312-2024 | |
| person.identifier.rid | AAN-1568-2020 | |
| person.identifier.rid | JAC-7345-2023 | |
| person.identifier.rid | AFS-1649-2022 | |
| person.identifier.rid | Y-1372-2019 | |
| person.identifier.rid | AAV-8016-2021 |
