<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

The harmonic residual index: a spectral purity metric for magnetic hyperthermia RF generators

dc.contributor.authorYoner, Serhat Ilgaz
dc.contributor.authorOzcan, Alpay
dc.contributor.authorAkin, Oguz
dc.date.accessioned2026-11-05T11:00:54Z
dc.date.issued2026
dc.description.abstractRF generators are core components of magnetic hyperthermia (MH) systems, yet output quality is rarely characterized beyond nominal frequency and amplitude. Harmonic distortion can introduce parasitic components that complicate reproducibility and accurate field characterization; MH-specific spectral quality indices remain limited. This study proposes two indices for RF generator output quality assessment in MH: the harmonic residual index ( HRI) and a simulation-derived harmonic specific absorption rate (SAR) contribution index ( Lambda & strns;SAR). A sinusoidal RF generator (50-200 kHz, 115 W) was evaluated with three coil configurations at 10%-100% power. Spatial magnetic-field measurements were acquired using a passive search coil, and HRI was computed pointwise to generate harmonic distortion maps. THD was computed from the same spectra for benchmarking. Spatial mean HRI ( HRI & horbar;) and THD ( THD & horbar;) were modelled using weighted power-law fitting. Inductive heating experiments (120-166.5 mg ml-1 MNP) evaluated the reliability of experimental calorimetry, motivating a shift toward simulation-based dosimetry. Finite element method (FEM) simulations of a simplified neck model driven by measured harmonics estimated relative harmonic SAR contributions and Lambda & strns;SAR. HRI & horbar; ranged from 0.17 +/- 0.04 to 16.41 +/- 3.48 (RMSE = 0.301-1.523) and increased monotonically with power level across all coils, while THD showed smaller variations and less spatially structured behaviour. Experimental heating trials yielded marginal temperature elevations (<= 2.5 degrees C) with quantization errors, demonstrating that standard calorimetry is metrologically insufficient for SAR derivation at clinical field intensities. Conversely Lambda & strns;SAR ranged from 2.23E + 4 to 2.70E + 6, indicating low harmonic contributions relative to the fundamental under the tested conditions. HRI enables spatially resolved quantification of RF generator spectral impurities in MH systems and provides greater spatial sensitivity than THD under the tested conditions. Combined with FEM screening of harmonic SAR contributions, the framework supports reproducible, standardized characterization of RF generator output quality for MH instrumentation quality assurance.
dc.description.issue35
dc.description.pages355403
dc.description.sponsorshipThis work was supported by the Bogazici University Research Fund under grant number 19661.
dc.description.volume59
dc.identifier.doi10.1088/1361-6463/ae9d8a
dc.identifier.issn0022-3727
dc.identifier.issn1361-6463
dc.identifier.urihttps://doi.org/10.1088/1361-6463/ae9d8a
dc.identifier.urihttps://openaccess.acibadem.edu.tr/handle/11443/10591
dc.identifier.wosWOS:001866497100001
dc.language.isoen
dc.publisherIOP Publishing Ltd
dc.relation.fundingBogazici University Research Fund(Bogazici University)
dc.relation.fundingBogazici University Research Fund [19661]
dc.relation.hasversion10.1088/1361-6463/ae9d8a
dc.relation.ispartofJOURNAL OF PHYSICS D-APPLIED PHYSICS
dc.subjectmagnetic hyperthermia
dc.subjectelectromagnetic safety
dc.subjectharmonic distortion
dc.subjectspecific absorption rate
dc.subjectspectral purity
dc.subjectradiofrequency characterization
dc.subjectCANCER-TREATMENT
dc.subjectNANOPARTICLES
dc.subjectDESIGN
dc.subjectCOIL
dc.subjectPhysics, Applied
dc.subjectPhysics
dc.titleThe harmonic residual index: a spectral purity metric for magnetic hyperthermia RF generators
dc.typeArticle
oaire.citation.editionScience Citation Index Expanded (SCI-EXPANDED)
oaire.citation.issue35
oaire.citation.volume59
person.identifier.ridAAS-8798-2020
person.identifier.ridOBN-9808-2025

Files

Collections