Effect of modified Blalock-Taussig shunt anastomosis angle and pulmonary artery diameter on pulmonary flow

dc.contributor.authorArnaz, Ahmet
dc.contributor.authorPiskin, Senol
dc.contributor.authorOguz, Gokece Nur
dc.contributor.authorYalcinbas, Yusuf
dc.contributor.authorPekkan, Kerem
dc.contributor.authorSarioglu, Tayyar
dc.date.accessioned2023-02-21T12:38:53Z
dc.date.available2023-02-21T12:38:53Z
dc.date.issued2018-01-01
dc.description.abstractObjective: This study aimed to identify the best graft-to-pulmonary artery (PA) anastomosis angle measuring pulmonary blood flow, wall shear stress (WSS), and shunt flow. Methods: A tetralogy of Fallot with pulmonary atresia computer model was used to study three different modified Blalock-Taussig shunt (mBTS) anastomosis angle configurations with three different PA diameter configurations. Velocity and WSS were analyzed, and the flow rates at the right PA (RPA) and left PA (LPA) were calculated. Results: A 4-mm and 8-mm diameter of RPA and LPA, respectively with vertical shunt angle produces the highest total flow. In the RPA larger diameter than the LPA configutations, the left-leaning shunt produces the lowest total PA flow whereas in the LPA larger diameter than the RPA configuratios, the right-leaning shunt produces the lowest total PA flow. Therefore, the shunt anastomosis should not be leaned through the narrow side of PA to reach best flow. As the flow inside the shunt increased, WSS also increased due to enhanced velocity gradients. Conclusion: The anastomosis angle between the conduit and PA affects the flow to PA. Vertical anastomosis configurations increase the total PA flow
dc.description.abstractthus, these configurations are preferable than the leaned configurations.
dc.description.issue1
dc.description.issueJUL
dc.description.pages2-8
dc.description.volume20
dc.identifier.doi10.14744/AnatolJCardiol.2018.54810
dc.identifier.urihttps://hdl.handle.net/11443/2441
dc.identifier.urihttp://dx.doi.org/10.14744/AnatolJCardiol.2018.54810
dc.identifier.wosWOS:000446230300004
dc.publisherTURKISH SOC CARDIOLOGY
dc.relation.ispartofANATOLIAN JOURNAL OF CARDIOLOGY
dc.subjectmodified Blalock-Taussig shunt
dc.subjectshunt stenosis
dc.subjectcomputational fluid dynamics
dc.subjecthemodynamic
dc.subjectsimulations
dc.titleEffect of modified Blalock-Taussig shunt anastomosis angle and pulmonary artery diameter on pulmonary flow
dc.typeArticle