Implementation and Dosimetric Evaluation of a Knowledge-Based IMRT Model for Left-Sided Breast Radiotherapy with DIBH
| dc.contributor.author | Senkesen, Oznur | |
| dc.contributor.author | Ispir, Emine Burcin | |
| dc.contributor.author | Aydin, Irem | |
| dc.contributor.author | Tezcanli, Evrim | |
| dc.date.accessioned | 2026-11-05T11:08:26Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Purpose: This study aimed to dosimetrically evaluate the plan quality of a knowledge-based planning (KBP) model developed from intensity-modulated radiation therapy (IMRT) plans for left-sided breast cancer treated with deep inspiration breath hold (DIBH), and to assess its clinical applicability. Materials and methods: Eighty patients previously treated with DIBH were included. A RapidPlan-based KBP model was developed using clinically approved plans (ClinP) within a Halcyon-equivalent workflow on the Ethos platform. Dosimetric performance of model-only plans (KBP) and plans refined with limited manual optimization (KBP+MP) was compared against ClinP for planning target volume (PTV) coverage and organ-at-risk (OAR) sparing. Results: The KBP model demonstrated satisfactory training performance, with acceptable coefficients of determination (R2) and mean squared error (MSE) values for most OARs. Both KBP and KBP+MP achieved PTV coverage comparable to ClinP, particularly for D95 and D98. In the left lung, V20 and D2% were reduced, and both the mean dose and D2% to the left anterior descending (LAD) artery were significantly lower in KBP plans, although lung V5 showed a slight increase. Discussion: Our findings support the clinical applicability of KBP. While KBP effectively reduces high-dose regions, it may increase low-dose exposure particularly in distant OARs such as the contralateral lung and breast. The KBP+MP approach provided more balanced OAR sparing while simplifying the overall planning workflow compared with manual methods. Conclusion: The KBP model demonstrated clinical feasibility for left-sided breast IMRT under DIBH conditions. Model-generated plans achieved target coverage comparable to clinically approved plans while providing acceptable OAR sparing. Although KBP alone tended to increase low-dose exposure in contralateral structures, limited manual refinement improved overall dose balance. These findings support the integration of structured KBP workflows into standardized DIBH breast IMRT planning. | |
| dc.description.issue | 5 | |
| dc.description.pages | e70599 | |
| dc.description.volume | 27 | |
| dc.identifier.doi | 10.1002/acm2.70599 | |
| dc.identifier.issn | 1526-9914 | |
| dc.identifier.uri | https://doi.org/10.1002/acm2.70599 | |
| dc.identifier.uri | https://openaccess.acibadem.edu.tr/handle/11443/11538 | |
| dc.identifier.wos | WOS:001778677200001 | |
| dc.language.iso | en | |
| dc.publisher | WILEY | |
| dc.relation.hasversion | 10.1002/acm2.70599 | |
| dc.relation.ispartof | JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | |
| dc.subject | DIBH | |
| dc.subject | Halcyon | |
| dc.subject | IMRT | |
| dc.subject | knowledge-based planning | |
| dc.subject | left-sided breast cancer | |
| dc.subject | RapidPlan | |
| dc.subject | MODULATED ARC THERAPY | |
| dc.subject | Radiology, Nuclear Medicine & Medical Imaging | |
| dc.title | Implementation and Dosimetric Evaluation of a Knowledge-Based IMRT Model for Left-Sided Breast Radiotherapy with DIBH | |
| dc.type | Article | |
| oaire.citation.edition | Science Citation Index Expanded (SCI-EXPANDED) | |
| oaire.citation.issue | 5 | |
| oaire.citation.volume | 27 | |
| person.identifier.orcid | 0009-0001-0142-9015 | |
| person.identifier.rid | QUS-3803-2026 | |
| person.identifier.rid | AAG-9602-2019 |
