Default-threshold operating-point validation of a commercial chest radiograph AI system for selected CT-anchored thoracic findings: a bi-national multicenter retrospective study
| dc.contributor.author | Basar, Yeliz | |
| dc.contributor.author | Seker, Mustafa Ege | |
| dc.contributor.author | Kirova-Nedyalkova, Galina Ivanova | |
| dc.contributor.author | Milkovska, Elina Plamenova | |
| dc.contributor.author | Manov, Boyan Emilov | |
| dc.contributor.author | Tamturk, Atahan | |
| dc.contributor.author | Tasci, Ilke | |
| dc.contributor.author | Karadag, Melih | |
| dc.contributor.author | Sarac, Nuri | |
| dc.contributor.author | Duzgun, Selin Ardali | |
| dc.contributor.author | Karakoc, Erencan | |
| dc.contributor.author | Karabulut, Ahmet | |
| dc.contributor.author | Kavi, Cemre | |
| dc.contributor.author | Buyukkirli, Kaan | |
| dc.contributor.author | Onal, Mehmet Onur | |
| dc.contributor.author | Alis, Deniz | |
| dc.contributor.author | Savas, Recep | |
| dc.contributor.author | Karaarslan, Ercan | |
| dc.contributor.author | Durhan, Gamze | |
| dc.date.accessioned | 2026-11-05T11:00:21Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | This retrospective bi-national multicenter diagnostic accuracy study evaluated the locked default-threshold performance of a commercial chest radiograph AI system for selected thoracic findings using a CT-anchored, radiographic-detectability reference framework. Consecutive eligible adult patients who underwent frontal chest radiography and chest CT at four tertiary-care centers in Turkey and Bulgaria between June and December 2024 were included. Reference labels were assigned using temporally paired CT, with adjudication of whether CT-confirmed abnormalities had a corresponding radiographic manifestation on the paired chest radiograph. For potentially dynamic findings, the allowable CT-CXR interval was restricted to <= 2 days. The AI system was evaluated at the manufacturer's default threshold of 0.50. Diagnostic performance was summarized using prevalence, sensitivity, specificity, positive predictive value, negative predictive value, and false-positive burden with 95% confidence intervals. The study included 940 patients with paired CXR-CT examinations. Reference-positive prevalence ranged from 2.2% for pneumothorax to 21.0% for pleural effusion. Sensitivity was highest for fracture (91%) and pneumothorax (90%) and lowest for atelectasis (64%); specificity ranged from 82% for consolidation/opacity to 98% for fracture and pneumothorax. PPV ranged from 43% to 63%, indicating a non-trivial false-positive burden at the evaluated operating point. Because continuous probability scores, human-reader comparison, and workflow outcomes were unavailable, these findings should be interpreted as default-threshold technical validation and support further evaluation of the system as radiologist-supervised decision support with local performance monitoring, rather than standalone diagnosis. | |
| dc.description.issue | 1 | |
| dc.description.pages | 26052 | |
| dc.description.volume | 16 | |
| dc.identifier.doi | 10.1038/s41598-026-55487-9 | |
| dc.identifier.issn | 2045-2322 | |
| dc.identifier.uri | https://doi.org/10.1038/s41598-026-55487-9 | |
| dc.identifier.uri | https://openaccess.acibadem.edu.tr/handle/11443/10400 | |
| dc.identifier.wos | WOS:001854933100001 | |
| dc.language.iso | en | |
| dc.publisher | NATURE PORTFOLIO | |
| dc.relation.hasversion | 10.1038/s41598-026-55487-9 | |
| dc.relation.ispartof | SCIENTIFIC REPORTS | |
| dc.subject | Artificial intelligence | |
| dc.subject | Chest radiography | |
| dc.subject | Computed tomography | |
| dc.subject | Diagnostic accuracy | |
| dc.subject | Thoracic imaging | |
| dc.subject | Multicenter validation | |
| dc.subject | Clinical decision support | |
| dc.subject | Multidisciplinary Sciences | |
| dc.subject | Science & Technology - Other Topics | |
| dc.title | Default-threshold operating-point validation of a commercial chest radiograph AI system for selected CT-anchored thoracic findings: a bi-national multicenter retrospective study | |
| dc.type | Article | |
| oaire.citation.edition | Science Citation Index Expanded (SCI-EXPANDED) | |
| oaire.citation.issue | 1 | |
| oaire.citation.volume | 16 | |
| person.identifier.rid | AAR-8643-2021 | |
| person.identifier.rid | HLV-9311-2023 | |
| person.identifier.rid | MFH-8346-2025 |
