Antimicrobial Susceptibility Test for the Determination of Resistant and Susceptible S. aureus and Enterococcus spp. Using a Multi-Channel Surface Plasmon Resonance Device

dc.contributor.authorUcak Ozkaya, Gulsum
dc.contributor.authorDurak, Muhammed Zeki
dc.contributor.authorAkyar, Isin
dc.contributor.authorKaratuna, Onur
dc.date.accessioned2023-02-21T12:34:46Z
dc.date.available2023-02-21T12:34:46Z
dc.date.issued2019-01-01
dc.description.abstractThe objective of this study was to investigate the development of a surface plasmon resonance (SPR) sensor platform equipped with multiple channels for the simultaneous determination of methicillin-resistant S. aureus (MRSA), methicillin-susceptible S. aureus (MSSA) and vancomycin-resistant Enterococcus (VRE), and vancomycin-susceptible Enterococcus (VSE). Drug resistance of S. aureus strains against cefoxitin and Enterococcus strains against vancomycin were investigated both using the minimum inhibitory concentration method (MIC) assay and the SPR system equipped with single and multiple channels. The MIC values of MRSA and MSSA ranged from 32 mu g/mL to >128 mu g/mL and from 1 mu g/mL to 4 mu g/mL, respectively. The MIC values of VRE and VSE were between 64 to >128 mu g/mL and 2-4 mu g/mL, respectively. With the multiple-channel system, the angle shifts of MRSA, MSSA, VRE and VSE were found to be -0.030 degrees and -0.260 degrees, -0.010 degrees and -0.090 degrees respectively. The antibiotic-resistant and susceptible strains were distinguished within 3 h for S. aureus strains and within 6 h for Enterococcus strains.
dc.description.issue4
dc.description.issueDEC
dc.description.volume9
dc.identifier.doi10.3390/diagnostics9040191
dc.identifier.urihttps://hdl.handle.net/11443/1806
dc.identifier.urihttp://dx.doi.org/10.3390/diagnostics9040191
dc.identifier.wosWOS:000506637600065
dc.publisherMDPI
dc.relation.ispartofDIAGNOSTICS
dc.subjectantimicrobial susceptibility
dc.subjectminimum inhibitory concentration assay
dc.subjectmethicillin-resistant S. aureus
dc.subjectnosocomial infection
dc.subjectsurface plasmon resonance
dc.subjectvancomycin-resistant Enterococcus
dc.titleAntimicrobial Susceptibility Test for the Determination of Resistant and Susceptible S. aureus and Enterococcus spp. Using a Multi-Channel Surface Plasmon Resonance Device
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Antimicrobial Susceptibility Test for the Determination of Resistant and Susceptible S. aureus and.pdf
Size:
7.17 MB
Format:
Adobe Portable Document Format

Collections