<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Polypropylene mesh reinforcement does not improve acute biomechanical properties in superior capsular reconstruction: an ovine model study

dc.contributor.authorKarademir, Gokhan
dc.contributor.authorDurbas, Atahan
dc.contributor.authorDiril, Sabri Kerem
dc.contributor.authorOzdemir, Yunus Emre
dc.contributor.authorTunali, Onur
dc.contributor.authorErsen, Ali
dc.contributor.authorAtalar, Ata Can
dc.date.accessioned2026-11-05T11:05:07Z
dc.date.issued2026
dc.description.abstractBackgroundSuperior capsular reconstruction (SCR) is a treatment option for irreparable rotator cuff tears (IRCTs), yet graft failure remains a significant limitation. While fascia (FA) grafts are commonly used, postoperative outcomes can be suboptimal, potentially contributing to higher mechanical failure rates. Polypropylene mesh (PM) augmentation has shown promise in improving soft-tissue repair strength, but its acute biomechanical efficacy in SCR remains insufficiently investigated. This study aimed to evaluate whether PM augmentation enhances the biomechanical stability of FA grafts in SCR using an ovine model.MethodsTen fresh-frozen ovine cadaveric shoulders were used to model IRCT. Only one shoulder per animal was included to ensure specimen independence. Specimens were randomly assigned to two treatment groups: FA-only SCR (FA-SCR) and PM-reinforced FA-SCR (PMFA-SCR). In the PMFA-SCR group, the mesh was placed within the FA graft prior to folding and suturing. Grafts were fixed to the glenoid and humerus using suture anchors, with two anchors placed on the glenoid anterosuperior/posterosuperior and two on the humerus footprint anterior/posterior in all specimens. Biomechanical testing was conducted with a custom device, with specimens mounted at 30 degrees abduction. Dynamic testing involved cyclic loading from 10 to 50 N at 1 Hz for 1000 cycles, with displacement and stiffness recorded. Immediately afterward, static load-to-failure testing was performed at a crosshead speed of 20 mm/min to determine the ultimate load, yield load, and failure mode. Data were analyzed using the Student's t-test.ResultsFA-SCR and PMFA-SCR demonstrated similar biomechanical performance, with comparable displacements both at the initial stage (p = 0.74) and after 1000 cycles (p = 0.83). No significant differences were observed in cumulative displacement (p = 0.63) or cyclic stiffness after the first or final cycle (p = 0.68 and p = 0.82). Static testing showed no significant differences in ultimate load-to-failure (p = 0.75), displacement (p = 0.57), yield load (p = 0.92), or final stiffness (p = 0.69).ConclusionsIn an acute ex vivo ovine model, PM augmentation did not improve the time-zero biomechanical performance of FA grafts in SCR, indicating that any potential benefit of mesh augmentation may be time-dependent and biologically mediated.Level of evidenceV
dc.description.issue1
dc.description.pages223
dc.description.sponsorshipThis study was supported by Acibadem Mehmet Ali Aydinlar University Scientific Research Projects Coordination Unit (ABAPKO) under the Expedited Grant Support category (Project Decision No: 2023/01-01) with a funding amount of 15,360.00 TL (approximately $820.00 USD at the exchange rate at the time).
dc.description.volume21
dc.identifier.doi10.1186/s13018-026-06740-4
dc.identifier.issn1749-799X
dc.identifier.urihttps://doi.org/10.1186/s13018-026-06740-4
dc.identifier.urihttps://openaccess.acibadem.edu.tr/handle/11443/11268
dc.identifier.wosWOS:001726585600001
dc.language.isoen
dc.publisherBMC
dc.relation.fundingAcibadem Mehmet Ali Aydinlar University Scientific Research Projects Coordination Unit
dc.relation.fundingAcibadem Mehmet Ali Aydinlar University Scientific Research Projects Coordination Unit [2023/01-01]
dc.relation.hasversion10.1186/s13018-026-06740-4
dc.relation.ispartofJOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH
dc.subjectSuperior capsular reconstruction
dc.subjectRotator cuff tears
dc.subjectIrreparable rotator cuff tears, Polypropylene mesh
dc.subjectBiomechanical study
dc.subjectOvine model, Fascia graft
dc.subjectDERMAL ALLOGRAFT
dc.subjectMASSIVE TEARS
dc.subjectREPAIR
dc.subjectAUGMENTATION
dc.subjectGRAFT
dc.subjectINTERPOSITION
dc.subjectMANAGEMENT
dc.subjectSTABILITY
dc.subjectOUTCOMES
dc.subjectOrthopedics
dc.titlePolypropylene mesh reinforcement does not improve acute biomechanical properties in superior capsular reconstruction: an ovine model study
dc.typeArticle
oaire.citation.editionScience Citation Index Expanded (SCI-EXPANDED)
oaire.citation.issue1
oaire.citation.volume21
person.identifier.ridAEY-1612-2022
person.identifier.ridPVE-4643-2026
person.identifier.ridB-2133-2016
person.identifier.ridAAS-8155-2020

Files

Collections