ChatGPT provides high-quality answers to FAQs about high tibial osteotomy despite low inter-rater agreement
| dc.contributor.author | Akcaalan, Serhat | |
| dc.contributor.author | Sahbat, Yavuz | |
| dc.contributor.author | Loddo, Glauco | |
| dc.contributor.author | Erden, Tunay | |
| dc.contributor.author | Kocaoglu, Baris | |
| dc.date.accessioned | 2026-11-05T11:02:33Z | |
| dc.date.issued | 2025 | |
| dc.description.abstract | Purpose High tibial osteotomy (HTO) is frequently used to treat knee malalignment in younger patients. Given the rise in online health information-seeking behaviour, this study aimed to evaluate the quality of ChatGPT-generated responses to frequently asked questions (FAQs) about HTO and to assess the reliability of two scoring systems used by orthopaedic surgeons.Methods Twenty-four FAQs were submitted to ChatGPT (GPT-4-turbo). Four orthopaedic surgeons independently rated the responses at two time points using: (1) a 4-point categorical scale (1 = excellent, 4 = poor), and (2) a 100-point numerical scale (0 = worst, 100 = best). Intra-observer reliability was assessed using weighted kappa (kappa) and intraclass correlation coefficients (ICC); inter-observer agreement was measured using ICC values.Results Most responses were rated positively, with over 70% considered 'excellent' or requiring minimal clarification. Intra-observer agreement was variable, ranging from kappa = 0.333 to 0.864 and ICC = 0.690-0.922. Inter-observer agreement was consistently low across both scales (ICC <= 0.390).Conclusion ChatGPT responses to HTO-related FAQs were rated as high quality by most evaluators. However, the low inter-observer agreement highlights the need for standardised evaluation tools and suggests that expert oversight remains essential when integrating AI-generated content into patient education.Level of Evidence Level V. | |
| dc.description.issue | 4 | |
| dc.description.pages | e70521 | |
| dc.description.volume | 12 | |
| dc.identifier.doi | 10.1002/jeo2.70521 | |
| dc.identifier.issn | 2197-1153 | |
| dc.identifier.uri | https://doi.org/10.1002/jeo2.70521 | |
| dc.identifier.uri | https://openaccess.acibadem.edu.tr/handle/11443/10933 | |
| dc.identifier.wos | WOS:001626248000001 | |
| dc.language.iso | en | |
| dc.publisher | WILEY | |
| dc.relation.hasversion | 10.1002/jeo2.70521 | |
| dc.relation.ispartof | JOURNAL OF EXPERIMENTAL ORTHOPAEDICS | |
| dc.subject | artificial intelligence | |
| dc.subject | ChatGPT | |
| dc.subject | high tibial osteotomy | |
| dc.subject | scoring system | |
| dc.subject | KNEE | |
| dc.subject | INTERNET | |
| dc.subject | Orthopedics | |
| dc.subject | Surgery | |
| dc.title | ChatGPT provides high-quality answers to FAQs about high tibial osteotomy despite low inter-rater agreement | |
| dc.type | Article | |
| oaire.citation.edition | Emerging Sources Citation Index (ESCI) | |
| oaire.citation.issue | 4 | |
| oaire.citation.volume | 12 | |
| person.identifier.orcid | 0000-0002-9963-5334 | |
| person.identifier.orcid | 0000-0001-7350-6422 | |
| person.identifier.orcid | 0000-0002-2537-0660 | |
| person.identifier.orcid | 0000-0002-0306-0143 | |
| person.identifier.orcid | 0000-0002-0926-5879 | |
| person.identifier.rid | GXF-0361-2022 | |
| person.identifier.rid | HIK-1232-2022 | |
| person.identifier.rid | W-7954-2018 | |
| person.identifier.rid | ABE-2103-2021 |