<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Clinical outcomes of intramedullary nailing for tibial shaft fractures caused by low-energy gunshot versus Gustilo-Anderson type I tibial shaft fractures

dc.contributor.authorBayram, Berhan
dc.contributor.authorAkcaalan, Serhat
dc.contributor.authorYozgatli, Tahir Koray
dc.contributor.authorTanriverdi, Bulent
dc.contributor.authorBilgili, Mustafa Gokhan
dc.contributor.authorKocaoglu, Baris
dc.date.accessioned2026-11-05T11:07:56Z
dc.date.issued2026
dc.description.abstractBackground Tibial shaft fractures caused by low-energy gunshot injuries represent a rare but challenging clinical problem. The optimal treatment approach, particularly in comparison with Gustilo-Anderson Type I open fractures, remains controversial. Methods This was a retrospective comparative study that included patients who underwent intramedullary nailing for tibial shaft fractures. Group 1 consisted of low-energy gunshot-induced fractures, while Group 2 included Gustilo-Anderson Type I open fractures. Demographic data, union time, Radiographic Union Score for Tibial Fractures (RUST), Johner-Wruhs functional classification, need for additional surgical intervention, and infection rates were compared. Results A total of 128 patients were included (68 in Group 1 and 60 in Group 2). No significant differences were observed between the groups regarding demographic characteristics, follow-up duration, union time, RUST scores, or Johner-Wruhs functional outcomes (p > 0.05). However, the infection rate was significantly higher in the low-energy gunshot group compared with the Gustilo-Anderson type I group (20.6% vs. 5.0%, p = 0.020).Nonunion and reoperation rates did not differ significantly between the groups. Conclusion Intramedullary nailing for tibial shaft fractures caused by low-energy gunshot injuries provides clinical and radiological outcomes comparable to those observed in Gustilo-Anderson type I open fractures. Nevertheless, these injuries appear to be associated with a higher risk of infection, warranting careful perioperative management and closer postoperative surveillance.
dc.description.issue1
dc.description.pages414
dc.description.volume21
dc.identifier.doi10.1186/s13018-026-06916-y
dc.identifier.issn1749-799X
dc.identifier.urihttps://doi.org/10.1186/s13018-026-06916-y
dc.identifier.urihttps://openaccess.acibadem.edu.tr/handle/11443/11498
dc.identifier.wosWOS:001823922500005
dc.language.isoen
dc.publisherBMC
dc.relation.hasversion10.1186/s13018-026-06916-y
dc.relation.ispartofJOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH
dc.subjectTibial shaft fracture
dc.subjectLow-energy gunshot injury
dc.subjectIntramedullary nailing
dc.subjectGustilo-Anderson Type I
dc.subjectInfection
dc.subjectLONG-BONES
dc.subjectCOMPLICATIONS
dc.subjectWOUNDS
dc.subjectOrthopedics
dc.titleClinical outcomes of intramedullary nailing for tibial shaft fractures caused by low-energy gunshot versus Gustilo-Anderson type I tibial shaft fractures
dc.typeArticle
oaire.citation.editionScience Citation Index Expanded (SCI-EXPANDED)
oaire.citation.issue1
oaire.citation.volume21
person.identifier.ridHIK-1232-2022
person.identifier.ridIAN-3404-2023
person.identifier.ridGRO-2123-2022
person.identifier.ridW-7954-2018
person.identifier.ridLDF-0758-2024

Files

Collections