Evaluation of optimal urine screening and confirmation cut-off values for opiates, at a national reference laboratory
dc.contributor.author | Karakukcu, Cigdem | |
dc.contributor.author | Ciraci, Mehmet Zahid | |
dc.contributor.author | Kocer, Derya | |
dc.contributor.author | Faydali, Mine Yuce | |
dc.contributor.author | Serdar, Muhittin Abdulkadir | |
dc.date.accessioned | 2023-02-21T12:37:32Z | |
dc.date.available | 2023-02-21T12:37:32Z | |
dc.date.issued | 2021-01-01 | |
dc.description.abstract | Objectives: To obtain optimal immunoassay screening and LC-MS/MS confirmation cut-offs for opiate group tests to reduce false positive (FP) and false negative (FN) rates. Methods: A total of 126 urine samples, -50 opiate screening negative, 76 positive according to the threshold of 300 ng/mL by CEDIA method - were confirmed by a full-validated in-house LC-MS/MS method. Sensitivity, specificity, FP, and FN rates were determined at cut-off concentrations of both 300 and 2,000 ng/mL formorphine and codeine, and 10 ng/mLfor heroinmetabolite 6-mono-acetyl-morphine (6-MAM). Results: All CEDIA opiate negative urine samples were negative for morphine, codeine and 6-MAM. Although sensitivity was 100\% for each cut-off | |
dc.description.abstract | specificity was 54.9\% at CEDIA cut-off 300 ng/mL vs. LC-MS/MS cut-off 300 ng/mL and, 75\% at CEDIA cut-off 2,000 ng/mL vs. LC-MS/MS cut-off 2,000 ng/mL. False positive rate was highest (45.1\%) at CEDIA cut-off 300 ng/mL. At CEDIA cut-off 2,000 ng/mL vs. LC-MS/MS cut-off 300 ng/mL, specificity increased to 82.4\% and FP rate decreased to 17.6\%. All 6-MAM positive samples had CEDIA concentration >= 2,000 ng/mL. Conclusions: 2,000 ng/mL for screening and 300 ng/mL for confirmation cut-offs are the most efficient thresholds for the lowest rate of FP opiate results. | |
dc.description.issue | 5 | |
dc.description.issue | OCT | |
dc.description.pages | 593-602 | |
dc.description.volume | 46 | |
dc.identifier.doi | 10.1515/tjb-2020-0614 | |
dc.identifier.uri | https://hdl.handle.net/11443/2259 | |
dc.identifier.uri | http://dx.doi.org/10.1515/tjb-2020-0614 | |
dc.identifier.wos | WOS:000712261700015 | |
dc.publisher | WALTER DE GRUYTER GMBH | |
dc.relation.ispartof | TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI | |
dc.subject | 6-MAM | |
dc.subject | codeine | |
dc.subject | confirmation | |
dc.subject | cut-off | |
dc.subject | immunoassay | |
dc.subject | LC-MS/MS | |
dc.subject | morphine | |
dc.subject | opiate | |
dc.subject | screening | |
dc.title | Evaluation of optimal urine screening and confirmation cut-off values for opiates, at a national reference laboratory | |
dc.type | Article |