Temporally Robust Machine-Learning-Assisted Impedance Line-Shape Analysis for Quantitative QCM Biosensing with DNA Hybridization Validation
| dc.contributor.author | Kirimli, Ceyhun E. | |
| dc.contributor.author | Elgun, Elcim | |
| dc.contributor.author | Tugtag, Selin Yagmur | |
| dc.date.accessioned | 2026-11-05T11:01:21Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Liquid-phase quartz crystal microbalance (QCM) biosensors are commonly quantified using scalar readouts such as frequency shift, dissipation, or bandwidth. Although useful, these descriptors discard resonance line-shape morphology that carries additional information for quantitative inference. Here, we present a machine-learning-assisted impedance line-shape workflow for temporally robust quantitative 10 MHz QCM biosensing. A passive microfluidic mixer generated controlled glycerol-water concentration gradients under constant total flow while complex impedance spectra were acquired in real time, and each sweep was parameterized using constrained Gaussian/Lorentzian models to obtain 52 physically interpretable descriptors spanning resistance, reactance, impedance magnitude, admittance components, and phase. The pipeline combines consensus outlier handling, training-fold mRMR feature ranking, and regression models evaluated under both shuffled five-fold cross-validation and a stricter temporally blocked protocol in which contiguous portions of the experiment are held out. The workflow achieved R2=0.948 under shuffled validation and R2=0.823 under seven-block temporal validation, the latter reducing prediction error by 48.4% relative to a row-matched Kanazawa frequency-shift baseline evaluated on the same sweeps. Feature-set ablation indicated that phase and conductance line-shape descriptors carry particularly strong temporally generalizable information. Applied to an experimental DNA hybridization assay in 1 & times; PBS, the workflow reduced mean absolute percentage concentration error from 21.02% to 10.73%, a 48.9% improvement over conventional Delta f calibration. Retaining resonance morphology therefore improves quantitative QCM biosensing beyond scalar frequency-shift calibration and provides an interpretable basis for AI-assisted electronic biosensors. | |
| dc.description.issue | 10 | |
| dc.description.pages | 574 | |
| dc.description.sponsorship | This research was partially funded by the Scientific and Technological Research Council of Turkiye, grant number 122E166. | |
| dc.description.volume | 16 | |
| dc.identifier.doi | 10.3390/bios16100574 | |
| dc.identifier.issn | 2079-6374 | |
| dc.identifier.uri | https://doi.org/10.3390/bios16100574 | |
| dc.identifier.uri | https://openaccess.acibadem.edu.tr/handle/11443/10707 | |
| dc.identifier.wos | WOS:001913306200001 | |
| dc.language.iso | en | |
| dc.publisher | MDPI | |
| dc.relation.funding | Scientific and Technological Research Council of Trkiye | |
| dc.relation.funding | Scientific and Technological Research Council of Trkiye [122E166] | |
| dc.relation.hasversion | 10.3390/bios16100574 | |
| dc.relation.ispartof | BIOSENSORS-BASEL | |
| dc.subject | quartz crystal microbalance | |
| dc.subject | QCM biosensors | |
| dc.subject | AI-assisted biosensing | |
| dc.subject | impedance spectroscopy | |
| dc.subject | resonance line-shape analysis | |
| dc.subject | temporally blocked validation | |
| dc.subject | interpretable machine learning | |
| dc.subject | mRMR feature ranking | |
| dc.subject | Kanazawa baseline | |
| dc.subject | microfluidic concentration profiling | |
| dc.subject | DNA hybridization | |
| dc.subject | concentration prediction | |
| dc.subject | QUARTZ-CRYSTAL MICROBALANCE | |
| dc.subject | CONTACT | |
| dc.subject | FREQUENCY | |
| dc.subject | IMMOBILIZATION | |
| dc.subject | SENSITIVITY | |
| dc.subject | RESONATORS | |
| dc.subject | ADMITTANCE | |
| dc.subject | ROUGHNESS | |
| dc.subject | MODEL | |
| dc.subject | FILMS | |
| dc.subject | Chemistry, Analytical | |
| dc.subject | Nanoscience & Nanotechnology | |
| dc.subject | Instruments & Instrumentation | |
| dc.subject | Chemistry | |
| dc.subject | Science & Technology - Other Topics | |
| dc.title | Temporally Robust Machine-Learning-Assisted Impedance Line-Shape Analysis for Quantitative QCM Biosensing with DNA Hybridization Validation | |
| dc.type | Article | |
| oaire.citation.edition | Science Citation Index Expanded (SCI-EXPANDED) | |
| oaire.citation.issue | 10 | |
| oaire.citation.volume | 16 |