Virtual Non-Iodine Coronary Calcium Scoring on Photon-Counting CT: Patient- and Plaque-Level Analysis
| dc.contributor.author | Orman, Mujgan | |
| dc.contributor.author | Alis, Deniz | |
| dc.contributor.author | Onal, Mehmet Onur | |
| dc.contributor.author | Seker, Mustafa Ege | |
| dc.contributor.author | Akyol, Ahmet | |
| dc.contributor.author | Alhan, Cem | |
| dc.contributor.author | Karaarslan, Ercan | |
| dc.date.accessioned | 2026-11-05T11:05:04Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Background/Objectives: Whether PCCT-derived virtual non-iodine (VNI) images can replace true non-contrast (TNC) for coronary artery calcium scoring (CACS) remains uncertain, particularly for small, low-density plaques. We aimed to evaluate agreement between VNI and TNC for CACS at the patient and lesion levels and to quantify risk-category reclassification. Methods: In this retrospective single-center sample (May 2024-May 2025), 211 patients without prior coronary intervention and with nonzero CAC on TNC underwent PCCT. VNI (55 keV, QIR 1; 60 keV, QIR 4; PureCalcium) and TNC were reconstructed with matched section thickness/increment and kernel. Agatston and total calcified volume were recorded. Paired comparisons used Wilcoxon tests; reclassification across CAC categories (0, 1-99, 100-399, >= 400) and lesion-level false negatives (FNs) were assessed with TNC as the reference. Results: Low-keV VNIs (55-60 keV) underestimated CAC versus TNC. The median Agatston score decreased from 35.9 (IQR, 10.3-121.2) on TNC to 23.6 at 55 keV (p = 0.0006) and 22.2 at 60 keV (p = 0.0003); the total volume declined from 37.8 mm(3) to 20.2 mm(3) (p = 0.001) and 18.3 mm(3) (p < 0.0001), respectively. More than half of patients were reassigned to a lower CAC category; despite no patient being CAC = 0 on TNC, 46.9% (55 keV) and 47.4% (60 keV) were labeled CAC = 0 on VNI. Because this study deliberately included only patients with nonzero CAC on the TNC reference, these CAC = 0 rates on VNI represent misclassification within a CAC-positive sample and should not be interpreted as population-level prevalence. At the lesion level, 95% of patients had >= 1 FN plaques (430 FN plaques total), typically small (median 8 mm(3)) and of low density (median Agatston 6). Conclusions: In this single-center sample with relatively low-burden calcification, low-keV VNI (55-60 keV) significantly underestimates CAC and down-classifies patients, with frequent false-zero assignments (defined as CAC_VNI = 0 despite CAC_TNC > 0) driven predominantly by small, low-density plaques. | |
| dc.description.issue | 4 | |
| dc.description.pages | 599 | |
| dc.description.volume | 16 | |
| dc.identifier.doi | 10.3390/diagnostics16040599 | |
| dc.identifier.issn | 2075-4418 | |
| dc.identifier.uri | https://doi.org/10.3390/diagnostics16040599 | |
| dc.identifier.uri | https://openaccess.acibadem.edu.tr/handle/11443/11263 | |
| dc.identifier.wos | WOS:001702347300001 | |
| dc.language.iso | en | |
| dc.publisher | MDPI | |
| dc.relation.hasversion | 10.3390/diagnostics16040599 | |
| dc.relation.ispartof | DIAGNOSTICS | |
| dc.subject | photon-counting CT | |
| dc.subject | coronary calcium | |
| dc.subject | virtual non-iodine | |
| dc.subject | Agatston | |
| dc.subject | risk reclassification | |
| dc.subject | COMPUTED-TOMOGRAPHY | |
| dc.subject | ANGIOGRAPHY | |
| dc.subject | Medicine, General & Internal | |
| dc.subject | General & Internal Medicine | |
| dc.title | Virtual Non-Iodine Coronary Calcium Scoring on Photon-Counting CT: Patient- and Plaque-Level Analysis | |
| dc.type | Article | |
| oaire.citation.edition | Science Citation Index Expanded (SCI-EXPANDED) | |
| oaire.citation.issue | 4 | |
| oaire.citation.volume | 16 | |
| person.identifier.orcid | 0000-0001-7664-5786 | |
| person.identifier.orcid | 0000-0001-9052-8121 | |
| person.identifier.rid | AAU-1490-2020 | |
| person.identifier.rid | HLV-9311-2023 | |
| person.identifier.rid | D-2112-2015 |
