Is the Nexfin finger cuff method for cardiac output measurement reliable during coronary artery bypass grafting? A prospective comparison with the echocardiography and FloTrac/Vigileo methods

dc.contributor.authorAriturk, Cem
dc.contributor.authorAcil, Meltem
dc.contributor.authorUlugol, Halim
dc.contributor.authorOzgen, Zehra Serpil Ustalar
dc.contributor.authorOkten, Eyup Murat
dc.contributor.authorDagdelen, Sinan
dc.contributor.authorKarabulut, Esref Hasan
dc.contributor.authorAlhan, Huseyin Cem
dc.contributor.authorToraman, Fevzi
dc.date.accessioned2023-02-21T12:32:21Z
dc.date.available2023-02-21T12:32:21Z
dc.date.issued2016-01-01
dc.description.abstractBackground/aim: The aim of the current study was to assess the accuracy of cardiac output (CO) measurements obtained by the Nexfin finger cuff method as compared with the FloTrac/Vigileo and echocardiography methods in coronary artery bypass grafting (CABG) patients. Materials and methods: First-time elective CABG patients were prospectively enrolled in this study and divided into three groups according to CO measurement method. CO measurements were performed simultaneously by three different contributors and were collected by the fourth one 24 h postoperative in the intensive care unit (ICU). Data were statistically analyzed. Results: Seventeen female and 13 male patients between 42 and 78 years of age (with a mean of 56 +/- 4) were the subjects of this study. The mean CO measurements were 5.9 +/- 1.4 L/min, 5.8 +/- 1.1 L/min, and 6.0 +/- 1.1 L/min for the Nexfin, FloTrac/Vigileo, and echocardiography methods, respectively (P > 0.05). The correlation values between Nexfin and FloTrac/Vigileo, Nexfin and echocardiography, and FloTrac/Vigileo and echocardiography were r = 0.445, r = 0.377, and r = 0.384, respectively (P < 0.05). Conclusion: Nexfin yielded results comparable to those obtained with FloTrac/Vigileo and echocardiography for the postoperative CO assessment of CABG patients. Nexfin may be used in uncomplicated, hemodynamically stable patients in ICU as a reliable and totally noninvasive method of CO measurement.
dc.description.issue2
dc.description.pages291-295
dc.description.volume46
dc.identifier.doi10.3906/sag-1406-32
dc.identifier.urihttps://hdl.handle.net/11443/1016
dc.identifier.urihttp://dx.doi.org/10.3906/sag-1406-32
dc.identifier.wosWOS:000370271100008
dc.publisherTUBITAK SCIENTIFIC \& TECHNICAL RESEARCH COUNCIL TURKEY
dc.relation.ispartofTURKISH JOURNAL OF MEDICAL SCIENCES
dc.subjectNoninvasive monitoring
dc.subjectechocardiography
dc.subjectpulse contour analysis
dc.titleIs the Nexfin finger cuff method for cardiac output measurement reliable during coronary artery bypass grafting? A prospective comparison with the echocardiography and FloTrac/Vigileo methods
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Is the Nexfin finger cuff method for cardiac output measurement reliable during coronary artery.pdf
Size:
249.47 KB
Format:
Adobe Portable Document Format

Collections