Browsing by Author "Kurt, Ismail"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item Comparison of four immunoassay analyzers for relationship between thyroid stimulating hormone (TSH) and free thyroxine (FT4)(TURKISH BIOCHEM SOC, 2015-01-01) Serdar, Muhittin A.; Ispir, Emre; Ozgurtas, Taner; Gulbahar, Ozlem; Ciraci, Zahid; Pasaoglu, Hatice; Kurt, IsmailObjective: There is an inverse log/linear relationship between TSH and FT4 due to the negative feedback of these hormones on the pituitary. The objective of our study was to compare this relationship of TSH and FT4 between four different immunoassay analyzers. Methods: In our study, four data sets obtained from the database of four different hospital laboratories each using only a single method of measurement was used to evaluate this relationship between TSH and FT4. These data sets with their assay methods include: 21.102 test results measured by Modular E170 Analyzer (Roche Diagnostics, Germany), 20.241 test results measured by Access DxI 800 Unicel (Beckman Coulter, USA), 22.444 test results measured by Architect i2000sr (Abbott Laboratories, Abbott Park, Illinois, U.S.A) and 20.200 test results measured by ADVIA Centaur XP (Siemens Diagnostics, Tarrytown, NY). Inverse logarithmic relationship were determined from each data sets and compared between analyzers. Results: The correlation coefficients were -0.439 {[}95\% CI, (-0.450)- (-0.428)], -0.488 {[}95\% CI, (-0.498)- (-0.478)], -0.353 {[}95\% CI, (-0.364)- (-0.342)], -0.430 {[}95\% CI, (-0.441)- (-0.419)] for DxI 800 Unicel, Modular E 170, Architect i2000sr and ADVIA Centaur XP, respectively. In our study, all immunoassay analyzers showed poor correlation in a concentration range of TSH between 1.0 to 10.0 uIU/mL and the inverse log/linear relationship was not observed. Inverse relationship between TSH and FT4 is the result of negative thyroid pituitary hypothalamic feedback mechanism and this relationship is important especially in the diagnosis and treatment of hypo and hyperthyroidism. In data sets obtained from four different immunoassay analyzers, poor and statistically different correlation was observed between analyzers at TSH values ranged from 1.0 to 10.0 uIU/mL compared with FT4. Conclusion: These variations between analyzers may affect the clinical decisions especially in the evaluation of subclinical hypothyroidism, clinicians and laboratory specialists should be aware of these situation.Item Two Cases of the Same Family with the Unusual Elevation of CA19-9 Levels(ORDEM MEDICOS, 2014-01-01) Uyanik, Metin; Sertoglu, Erdim; Serdar, Muhittin A.; Aydin, Fevzi N.; Ozgurtas, Taner; Kurt, IsmailIntroduction: Serum carbohydrate associated antigen (CA19-9) is widely used marker in clinical practice and shows small increases in a few benign diseases. Here we report two cases, a mother and her daughter with slightly elevated CA19-9 levels not accompanied by any clinical pathology. Case Presentation: The mother with elevated CA19-9 level (89.90 U/mL