Item Is robotic radical nephroureterectomy a safe alternative to open approach: The first prospective analysis(PAGEPRESS PUBL, 2021-01-01) Mourmouris, Panagiotis; Argun, Omer Burak; Tzelves, Lazaros; Tuna, Mustafa Bilal; Gourtzelidou, Maria; Tziotis, Andreas; Kural, Ali Riza; Skolarikos, AndreasPurpose: To test the efficacy and safety profile of robotic radical nephroureterectomy compared to the open approach. Methods: We enrolled 45 consecutive patients who suffered from non-metastatic, upper urinary tract urothelial carcinoma from September 2019 to March 2021 and underwent radical nephroureterectomy. Patients were divided in two groups: group A consisted of 29 patients (open approach) and group B consisted of 16 patients (robotic approach). The factors which were taken into consideration were age, sex, body mass index, tumour size, side and grade, cancer stage, ASA score, operation time, drain removal time, foley time, hospitalization time, estimated blood loss, surgical margins, preoperative and postoperative creatinine, Hct and bladder recurrences. Statistical analysis was performed with the use of SPSS version 26 and p < 0.05 was the cut-off for reaching statistical significance. Results: The mean age in group 1 was 67.12 years and in group 2 68.12 years, whereas the mean body mass index (BMI) in group 1 was 26.54 kg/m(2) and in group 2 25.20 kg/m(2). Operative time was better in group A (124 vs 186 mins p < 0.001) and estimated blood loss were better in group B compared to group A (137 vs 316 ml p < 0.001). Length of stay (LOS) was significantly less in the robotic group (5.75 vs 4.3 days p = 0.003) and the same applied for time required for drain removal (4.5 vs 33 days p = 0.006). Conclusions: Robotic radical nephroureterectomy is a safe and efficient alternative to open approach. It provides a favorable perioperative profile in patients suffering from upper urinary tract carcinoma without metastasis.Item Minimizing Ports During Robotic Partial Nephrectomy(SOC LAPAROENDOSCOPIC SURGEONS, 2016-01-01) Argun, Omer Burak; Mourmouris, Panagiotis; Tufek, Ilter; Obek, Can; Tuna, Mustafa Bilal; Keskin, Selcuk; Kural, Ali RizaBackground and Objective: Robotic upper urinary tract surgery is in most of the cases performed utilizing a standard 5 port configuration. Fewer ports can potentially produce a less invasive operation. Taking in consideration the above we report a novel technique for robot assisted laparoscopic partial nephrectomy utilizing fewer ports and we test its feasibility and safety profile. Methods: Data on 11 robot-assisted laparoscopic partial nephrectomies performed by using our technique from February 2015 through June 2015 were retrospectively analyzed. The robotic platform used was DaVinci Xi (Intuitive Surgical, Inc., Sunnyvale, California, USA) with a 3-arm setup. The AirSeal system (SurgiQuest, Milford, Connecticut, USA) was used as a port allowing simultaneous introduction of 2 instruments for the bedside surgeon, obviating the need for an additional (fourth) robotic arm. A long suction-and-irrigation device and atraumatic grasping forceps were used. Both instruments were introduced through the trocar of the AirSeal system, making simultaneous introduction and use possible. We preferred the long suction-and-irrigation device, because it minimizes collision of the instruments. Results: Mean age and BMI of the patients were 55 +/- 14.6 y and 29.18 +/- 6.85, respectively. Seven tumors were on the right side and 4 were on the left. The mean size of the tumors was 32.45 mm (+/- 11.31). Surgical time was 132.2 minutes (+/- 37.17), with an estimated blood loss and ischemia time of 103.63 mL (+/- 65.92) and 16.72 minutes (+/- 9.52), respectively. One patient had postoperative bleeding that was resolved without transfusion. The median hospitalization period was 3.9 d (+/- 0.53). Loss of intra-abdominal pressure was not observed, and pressure was stable at 10 mm Hg. Conclusion: The AirSeal System and its valveless trocar eliminated the need for an additional port placement in our series. The technique is feasible, safe, and reproducible