An Easy Modification of Tube Graft Interposition During Fenestration in Borderline Fontan Circulation

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

dc.identifier.issn

dc.identifier.doi

10.1016/j.athoracsur.2015.04.102

dc.identifier.other

dc.description.volume

100

dc.description.issue

4
OCT

Publisher

ELSEVIER SCIENCE INC

DOI

10.1016/j.athoracsur.2015.04.102

Abstract

One of the options for the management of borderline/ failing extracardiac Fontan circulation is surgical creation of an atrial fenestration to decompress the systemic venous compartment and improve cardiac output. Depending on the body surface area of the patient, a 5- to 10-mm polytetrafluoroethylene (PTFE) tube graft can be used. When fenestration is required in a patient with failing Fontan circulation, particularly in redo cases, application of a side-biting clamp may be challenging because of adhesions and a thickened atrial wall. In this article, we present our off-pump technique of atrial-side anastomosis of PTFE graft interposition between an extracardiac Fontan conduit and the atrium without using a side-biting clamp. (C) 2015 by The Society of Thoracic Surgeons