Comparison of the Trendelenburg position versus upper-limb tourniquet on internal jugular vein diameter

dc.contributor.authorKaraaslan, Pelin
dc.contributor.authorGokay, Banu Vural
dc.contributor.authorKarakaya, Muhammet Ahmet
dc.contributor.authorDarcin, Kamil
dc.contributor.authorKarakaya, Afak Durur
dc.contributor.authorOrmeci, Tugrul
dc.contributor.authorKose, Emine Arzu
dc.date.accessioned2023-02-21T12:35:08Z
dc.date.available2023-02-21T12:35:08Z
dc.date.issued2017-01-01
dc.description.abstractBACKGROUND: Central venous cannulation is a necessary invasive procedure for fluid management, haemodynamic monitoring and vasoactive drug therapy. The right internal jugular vein (RIJV) is the preferred site. Enlargement of the jugular vein area facilitates catheterization and reduces complication rates. Common methods to enlarge the RIJV cross-sectional area are the Trendelenburg position and the Valsalva maneuver. OBJECTIVE: Compare the Trendelenburg position with upper-extremity venous return blockage using the tourniquet technique. DESIGN: Prospective clinical study. SETTING: University hospital. SUBJECTS AND METHODS: Healthy adult volunteers (American Society of Anesthesiologists class I) aged 18-45 years were included in the study. The first measurement was made when the volunteers were in the supine position. The RIJV diameter and cross-sectional area were measured from the apex of the triangle formed by the clavicle and the two ends of the sternocleidomastoid muscle, which is used for the conventional approach. The second measurement was performed in a 20 degrees Trendelenburg position. After the drainage of the veins using an Esbach bandage both arms were cuffed. The third measurement was made when tourniquets were inflated. MAIN OUTCOME MEASURE(S): Hemodynamic measurements and RIJV dimensions. RESULTS: In 65 volunteers the diameter and cross-sectional area of the RIJV were significantly widened in both Trendelenburg and tourniquet measurements compared with the supine position (P<.001 for both measures). Measurements using the upper extremity tourniquet were significantly larger than Trendelenburg measurements (P=.002 and <.001 for cross-sectional area and diameter, respectively). CONCLUSION: Channelling of the upper-extremity venous return to the jugular vein was significantly superior when compared with the Trendelenburg position and the supine position. LIMITATIONS: No catheterization and study limited to healthy volunteers.
dc.description.issue4
dc.description.issueJUL-AUG
dc.description.pages308-312
dc.description.volume37
dc.identifier.doi10.5144/0256-4947.2017.308
dc.identifier.urihttps://hdl.handle.net/11443/1876
dc.identifier.urihttp://dx.doi.org/10.5144/0256-4947.2017.308
dc.identifier.wosWOS:000407680900007
dc.publisherK FAISAL SPEC HOSP RES CENTRE
dc.relation.ispartofANNALS OF SAUDI MEDICINE
dc.titleComparison of the Trendelenburg position versus upper-limb tourniquet on internal jugular vein diameter
dc.typeArticle

Files

Collections