Comparison of anti-embolic protection with proximal balloon occlusion and filter devices during carotid artery stenting: clinical and procedural outcomes

dc.contributor.authorTatli, Ersan
dc.contributor.authorButurak, Ali
dc.contributor.authorGrunduz, Yasemin
dc.contributor.authorDogan, Emir
dc.contributor.authorAlkan, Mustafa
dc.contributor.authorSayin, Murat
dc.contributor.authorYilmaztepe, Mustafa
dc.contributor.authorAtakay, Selcuk
dc.date.accessioned2023-02-21T12:36:12Z
dc.date.available2023-02-21T12:36:12Z
dc.date.issued2013-01-01
dc.description.abstractAim: The objective of this study was to compare the periprocedural and clinical outcomes after carotid artery stenting (CAS) with proximal protection devices versus with distal protection devices. Material and methods: Patients with internal carotid artery (ICA) stenosis undergoing CAS with cerebral embolic protection were randomly assigned to proximal balloon occlusion or distal filter protection. Adverse events were defined as death, major stroke, minor stroke, transient ischemic attack (TIA) and myocardial infarction (MI). Periprocedural and 30-day adverse events and ICA vasospasm rates were compared between the two embolic protection groups. Results: Eighty-eight consecutive patients were randomized: 48 patients with proximal protection (mean age 68.8 +/- 13.6, 66\% male) and 40 patients with a distal protection device (mean age 65.4 +/- 12.3
dc.description.abstract70\% male). There was no significant difference in periprocedural or 30-day adverse event rates between the two groups (p > 0.05). However, there was a higher periprocedural ICA vasospasm rate in the distal filter protection group (9 patients, 23\%) compared with the proximal balloon occlusion group (1 patient, 2\%) (p = 0.019). Conclusions: There was no difference between the clinical periprocedural and 30-day adverse event rates of distal filter and proximal balloon protection systems. However, distal filter protection systems showed higher rates of periprocedural ICA vasospasm.
dc.description.issue3
dc.description.issueSEP
dc.description.pages221-227
dc.description.volume9
dc.identifier.doi10.5114/pwki.2013.37499
dc.identifier.urihttps://hdl.handle.net/11443/2064
dc.identifier.urihttp://dx.doi.org/10.5114/pwki.2013.37499
dc.identifier.wosWOS:000324967000004
dc.publisherTERMEDIA PUBLISHING HOUSE LTD
dc.relation.ispartofPOSTEPY W KARDIOLOGII INTERWENCYJNEJ
dc.subjectcarotid artery stenosis
dc.subjectprotection devices
dc.subjectstenting
dc.titleComparison of anti-embolic protection with proximal balloon occlusion and filter devices during carotid artery stenting: clinical and procedural outcomes
dc.typeArticle