Araştırma Çıktıları
Permanent URI for this communityhttps://hdl.handle.net/11443/931
Browse
8 results
Search Results
Item The Biological Variation Data Critical Appraisal Checklist: A Standard for Evaluating Studies on Biological Variation(AMER ASSOC CLINICAL CHEMISTRY, 2018-01-01) Aarsand, Aasne K.; Roraas, Thomas; Fernandez-Calle, Pilar; Ricos, Carmen; Diaz-Garzon, Jorge; Jonker, Niels; Perich, Carmen; Gonzalez-Lao, Elisabet; Carobene, Anna; Minchinela, Joana; Coskun, Abdurrahman; Simon, Margarita; Alvarez, Virtudes; Bartlett, William A.; Fernandez-Fernandez, Pilar; Boned, Beatriz; Braga, Federica; Corte, Zoraida; Aslan, Berna; Sandberg, Sverre; Chem, European Federation Clinical; Variation, Working Grp Biological; Biological, Task \& Finish GrpBACKGROUND: Concern has been raised about the quality of available biological variation (BV) estimates and the effect of their application in clinical practice. A European Federation of Clinical Chemistry and Laboratory Medicine Task and Finish Group has addressed this issue. The aim of this report is to (a) describe the Biological Variation Data Critical Appraisal Checklist (BIVAC), which verifies whether publications have included all essential elements that may impact the veracity of associated BV estimates, (b) use the BIVAC to critically appraise existing BV publications on enzymes, lipids, kidney, and diabetes-related measurands, and (c) apply metaanalysis to deliver a global within-subject BV (CVI) estimate for alanine aminotransferase (ALT). METHODS: In the BIVAC, publications were rated as A, B, C, or D, indicating descending compliance for 14 BIVAC quality items, focusing on study design, methodology, and statistical handling. A D grade indicated that associated BV estimates should not be applied in clinical practice. Systematic searches were applied to identify BV studies for 28 different measurands. RESULTS: In total, 128 publications were identified, providing 935 different BV estimates. Nine percent achieved D scores. Outlier analysis and variance homogeneity testing were scored as C in >60\% of 847 cases. Metaanalysis delivered a CVI estimate for ALT of 15.4\%. CONCLUSIONS: Application of BIVAC to BV publications identified deficiencies in required study detail and delivery, especially for statistical analysis. Those deficiencies impact the veracity of BV estimates. BV data from BIVAC-compliant studies can be combined to deliver robust global estimates for safe clinical application. (c) 2017 American Association for Clinical ChemistryItem Biological variation data for lipid cardiovascular risk assessment biomarkers. A systematic review applying the biological variation data critical appraisal checklist (BIVAC)(ELSEVIER, 2019-01-01) Diaz-Garzon, Jorge; Fernandez Calle, Pilar; Minchinela, Joana; Aarsand, Aasne K.; Bartlett, William A.; Aslan, Berna; Boned, Beatriz; Braga, Federica; Carobene, Anna; Coskun, Abdurrahman; Gonzalez-Lao, Elisabet; Jonker, Niels; Marques-Garcia, Fernando; Perich, Carmen; Ricos, Carmen; Simon, Margarita; Sandberg, SverreBackground: Biological variation (BV) data can be used to set analytical performance specifications (APS) for lipid assays. Poor performance will impact upon the efficacy of international guidelines for cardiovascular risk assessment (CVR) and relevant clinical decision limits. This systematic review applies the Biological Variation Data Critical Appraisal Checklist (BIVAC) to published studies of BV of CVR biomarkers enabling metanalysis of the data. Methods: Studies of BV of total cholesterol, HDL-cholesterol, LDL-cholesterol, triglycerides and apolipoproteins A(1) and B, retrieved using a systematic literature search, were evaluated and graded using the BIVAC. Meta analysis of CV1 and CVG estimates were performed utilizing weightings based upon BIVAC grades and the width of the data confidence intervals. Results: Applying the BIVAC, ten publications were graded as D, 43 as C, 5 as B and 1 as A (fully compliant). A total of 196 CV1 and 87 CVG estimates were available for the different lipid measurands. The meta-analysis-derived BV data estimates were generally concordant with those in the online 2014 BV database. Conclusions: Application of BIVAC identifies BV data suitable for many important applications including setting APS. Additionally, this review identifies a need for new BIVAC compliant studies to deliver BV reference data in different subpopulations.Item The EuBIVAS Project: Within- and Between-Subject Biological Variation Data for Serum Creatinine Using Enzymatic and Alkaline Picrate Methods and Implications for Monitoring(AMER ASSOC CLINICAL CHEMISTRY, 2017-01-01) Carobene, Anna; Marino, Irene; Coskun, Abdurrahman; Serteser, Mustafa; Unsal, Ibrahim; Guerra, Elena; Bartlett, William A.; Sandberg, Sverre; Aarsand, Aasne Karine; Sylte, Marit Sverresdotter; Roraas, Thomas; Solvik, Una Orvim; Fernandez-Calle, Pilar; Diaz-Garzon, Jorge; Tosato, Francesca; Plebani, Mario; Jonker, Niels; Barla, Gerhard; Ceriotti, Ferruccio; Variation, E.F.L.M. Working Grp BiolBACKGROUND: The European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) European Biological Variation Study (EuBIVAS) has been established to deliver rigorously determined biological variation (BV) indices. EuBIVAS determined BV for serum creatinine using the enzymatic and alkaline picrate measurement methods. METHOD: In total, 91 healthy individuals (38 males, 53 femalesItem The EuBIVAS: Within- and Between-Subject Biological Variation Data for Electrolytes, Lipids, Urea, Uric Acid, Total Protein, Total Bilirubin, Direct Bilirubin, and Glucose(AMER ASSOC CLINICAL CHEMISTRY, 2018-01-01) Aarsand, Aasne K.; Diaz-Garzon, Jorge; Fernandez-Calle, Pilar; Guerra, Elena; Locatelli, Massimo; Bartlett, William A.; Sandberg, Sverre; Roraas, Thomas; Ceriotti, Ferruccio; Solvik, Una Orvim; Sylte, Marit Sverresdotter; Coskun, Abdurrahman; Serteser, Mustafa; Unsal, Ibrahim; Tosato, Francesca; Plebani, Mario; Jonker, Niels; Barla, Gerhard; Carobene, Anna; Chem, European Federation ClinicalBACKGROUND: The European Federation of Clinical Chemistry and Laboratory Medicine European Biological Variation Study (EuBIVAS) has been established to deliver rigorously determined data describing biological variation (BV) of clinically important measurands. Here, EuBIVAS-based BV estimates of serum electrolytes, lipids, urea, uric acid, total protein, total bilirubin, direct bilirubin, and glucose, as well as their associated analytical performance specifications (APSs), are presented. METHOD: Samples were drawn from 91 healthy individuals (38 male, 53 femaleItem The European Biological Variation Study (EuBIVAS): a summary report(WALTER DE GRUYTER GMBH, 2022-01-01) Carobene, Anna; Aarsand, Aasne K.; Bartlett, William A.; Coskun, Abdurrahman; Diaz-Garzon, Jorge; Fernandez-Calle, Pilar; Guerra, Elena; Jonker, Niels; Locatelli, Massimo; Plebani, Mario; Sandberg, Sverre; Ceriotti, FerruccioBiological variation (BV) data have many important applications in laboratory medicine. Concerns about quality of published BV data led the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) 1st Strategic Conference to indicate need for new studies to generate BV estimates of required quality. In response, the EFLM Working Group on BV delivered the multicenter European Biological Variation Study (EuBIVAS). This review summarises the EuBIVAS and its outcomes. Serum/plasma samples were taken from 91 ostensibly healthy individuals for 10 consecutive weeks at 6 European centres. Analysis was performed by Siemens ADVIA 2400 (clinical chemistry), Cobas Roche 8000, c702 and e801 (proteins and tumor markers/hormones respectively), ACL Top 750 (coagulation parameters), and IDS iSYS or DiaSorin Liaison (bone biomarkers). A strict preanalytical and analytical protocol was applied. To determine BV estimates with 95\% CI, CV-ANOVA after analysis of outliers, homogeneity and trend analysis or a Bayesian model was applied. EuBIVAS has so far delivered BV estimates for 80 different measurands. Estimates for 10 measurands (Non-HDL Cholesterol, S100-beta protein, neuron-specific enolase, soluble transferrin receptor, intact fibroblast growth-factor-23, uncarboxylated-unphosphorylated matrix-Gla protein, human epididymis protein-4, free, conjugated and \%free prostate-specific antigen), prior to EuBIVAS, have not been available. BV data for creatinine and troponin I were obtained using two analytical methods in each case. The EuBIVAS has delivered high-quality BV data for a wide range of measurands. The BV estimates are for many measurands lower than those previously reported, having an impact on the derived analytical performance specifications and reference change values.Item Biological Variation Estimates Obtained from 91 Healthy Study Participants for 9 Enzymes in Serum(AMER ASSOC CLINICAL CHEMISTRY, 2017-01-01) Carobene, Anna; Roraas, Thomas; Solvik, Una Orvim; Sylte, Marit Sverresdotter; Sandberg, Sverre; Guerra, Elena; Marino, Irene; Jonker, Niels; Barla, Gerhard; Bartlett, William A.; Fernandez-Calle, Pilar; Diaz-Garzon, Jorge; Tosato, Francesca; Plebani, Mario; Coskun, Abdurrahman; Serteser, Mustafa; Unsal, Ibrahim; Ceriottil, Ferruccio; Biological, E.F.L.M. Working GrpBACKGROUND: We sought to develop estimates of biological variation (BV) for 9 enzymes in blood serum as part of the European Biological Variation Study. METHODS: Ninety-one healthy study participants (38 male and 53 female, 21-69 years old) were phlebotomized in each of 10 consecutive weeks at 6 European laboratories. The same preanalytical sample-handling protocol was followed at each center before transport to San Raffaele Hospital, Milan, Italy, for analysis. Sera were stored at -80 degrees C before analysis in duplicate within a single run on an ADVIA 2400 Clinical Chemistry System (Siemens Healthcare) following a protocol designed to minimize analytical imprecision. Assay traceability was established using frozen sera with target values assigned by reference methods. The results were subjected to outlier analysis before CV-ANOVA to deliver valid BV estimates. Results for 9 enzymes were subsequently partitioned for graphical display allowing visual assessment of the effects of country of origin, sex, and age on BV estimates. RESULTS: We found no effect of country upon the observed variation, but overall sex-related differences were evident for alanine amino transferase (ALT), gamma-glutamyl transferase (GGT), and creatine kinase (CK). The following estimates for within-subject BV (CVI) and between-subject BV (CVG), respectively, were obtained: ALT: 9.3\%, 28.2\%Item Within- and between-subject biological variation data for tumor markers based on the European Biological Variation Study(WALTER DE GRUYTER GMBH, 2022-01-01) Coskun, Abdurrahman; Aarsand, Aasne K.; Sandberg, Sverre; Guerra, Elena; Locatelli, Massimo; Diaz-Garzon, Jorge; Fernandez-Calle, Pilar; Ceriotti, Ferruccio; Jonker, Niels; Bartlett, William A.; Carobene, Anna; Chem, European Federation ClinicalObjectives: Reliable biological variation (BV) data are required for the clinical use of tumor markers in the diagnosis and monitoring of treatment effects in cancer. The European Biological Variation Study (EuBIVAS) was established by the EFLM Biological Variation Working Group to deliver BV data for clinically important measurands. In this study, EuBIVAS-based BV estimates are provided for cancer antigen (CA) 125, CA 15-3, CA 19-9, carcinoembryonic antigen, cytokeratin-19 fragment, alpha-fetoprotein and human epididymis protein 4. Methods: Subjects from five European countries were enrolled in the study, and weekly samples were collected from 91 healthy individuals (53 females and 38 malesItem Long-term within- and between-subject biological variation of 29 routine laboratory measurands in athletes(WALTER DE GRUYTER GMBH, 2022-01-01) Diaz-Garzon, Jorge; Fernandez-Calle, Pilar; Aarsand, Aasne K.; Sandberg, Sverre; Coskun, Abdurrahaman; Carobene, Anna; Jonker, Niels; Itkonen, Outi; Bartlett, William A.; Buno, Antonio; Chem, European Federation ClinicalObjectives Within- and between-subject biological variation (BV) estimates have many applications in laboratory medicine. However, robust high-quality BV estimates are lacking for many populations, such as athletes. This study aimed to deliver BV estimates of 29 routine laboratory measurands derived from a Biological Variation Data Critical Appraisal Checklist compliant design in a population of high-endurance athletes. Methods Eleven samples per subject were drawn from 30 triathletes monthly, during a whole sport season. Serum samples were measured in duplicate for proteins, liver enzymes, lipids and kidney-related measurands on an Advia2400 (Siemens Healthineers). After outlier and homogeneity analysis, within-subject (CVI) and between-subject (CVG) biological variation estimates were delivered (CV-ANOVA and log-ANOVA, respectively) and a linear mixed model was applied to analyze the effect of exercise and health related variables. Results Most CVI estimates were similar or only slightly higher in athletes compared to those reported for the general population, whereas two- to three-fold increases were observed for amylase, ALT, AST and ALP. No effect of exercise and health related variables were observed on the CVI estimates. For seven measurands, data were not homogeneously distributed and BV estimates were therefore not reported. Conclusions The observation of higher CVI estimates in athletes than what has been reported for the general population may be related to physiological stress over time caused by the continuous practice of exercise. The BV estimates derived from this study could be applied to athlete populations from disciplines in which they exercise under similar conditions of intensity and duration.