Temporally Robust Machine-Learning-Assisted Impedance Line-Shape Analysis for Quantitative QCM Biosensing with DNA Hybridization Validation
Loading...
Date
Journal Title
Journal ISSN
Volume Title
dc.identifier.issn
2079-6374
dc.identifier.doi
10.3390/bios16100574
dc.identifier.other
dc.description.volume
16
dc.description.issue
10
Publisher
MDPI
DOI
10.3390/bios16100574
10.3390/bios16100574
10.3390/bios16100574
Abstract
Liquid-phase quartz crystal microbalance (QCM) biosensors are commonly quantified using scalar readouts such as frequency shift, dissipation, or bandwidth. Although useful, these descriptors discard resonance line-shape morphology that carries additional information for quantitative inference. Here, we present a machine-learning-assisted impedance line-shape workflow for temporally robust quantitative 10 MHz QCM biosensing. A passive microfluidic mixer generated controlled glycerol-water concentration gradients under constant total flow while complex impedance spectra were acquired in real time, and each sweep was parameterized using constrained Gaussian/Lorentzian models to obtain 52 physically interpretable descriptors spanning resistance, reactance, impedance magnitude, admittance components, and phase. The pipeline combines consensus outlier handling, training-fold mRMR feature ranking, and regression models evaluated under both shuffled five-fold cross-validation and a stricter temporally blocked protocol in which contiguous portions of the experiment are held out. The workflow achieved R2=0.948 under shuffled validation and R2=0.823 under seven-block temporal validation, the latter reducing prediction error by 48.4% relative to a row-matched Kanazawa frequency-shift baseline evaluated on the same sweeps. Feature-set ablation indicated that phase and conductance line-shape descriptors carry particularly strong temporally generalizable information. Applied to an experimental DNA hybridization assay in 1 & times; PBS, the workflow reduced mean absolute percentage concentration error from 21.02% to 10.73%, a 48.9% improvement over conventional Delta f calibration. Retaining resonance morphology therefore improves quantitative QCM biosensing beyond scalar frequency-shift calibration and provides an interpretable basis for AI-assisted electronic biosensors.
Description
Keywords
quartz crystal microbalance , QCM biosensors , AI-assisted biosensing , impedance spectroscopy , resonance line-shape analysis , temporally blocked validation , interpretable machine learning , mRMR feature ranking , Kanazawa baseline , microfluidic concentration profiling , DNA hybridization , concentration prediction , QUARTZ-CRYSTAL MICROBALANCE , CONTACT , FREQUENCY , IMMOBILIZATION , SENSITIVITY , RESONATORS , ADMITTANCE , ROUGHNESS , MODEL , FILMS , Chemistry, Analytical , Nanoscience & Nanotechnology , Instruments & Instrumentation , Chemistry , Science & Technology - Other Topics