Araştırma Çıktıları
Permanent URI for this communityhttps://hdl.handle.net/11443/931
Browse
5 results
Search Results
Item Efficacy of PET-CT in the prediction of metastatic adrenal masses that are detected on follow-up of the patients with prior nonadrenal malignancy: A nationwide multicenter case-control study(LIPPINCOTT WILLIAMS \& WILKINS, 2022-01-01) Arikan, Akif Enes; Makay, Ozer; Teksoz, Serkan; Vatansever, Safa; Alptekin, Husnu; Albeniz, Gurcan; Demir, Ali; Ozpek, Adnan; Tunca, FatihMetastasis is the second most common type of adrenal gland mass. In patients undergoing follow-up for nonadrenal malignancy, adrenalectomy is performed when metastasis to adrenal gland is suspected on the basis of positron emission tomography-computed tomography (PET-CT) imaging. This study investigated the efficacy of PET-CT in the discrimination of metastatic lesions from nonmetastatic lesions in the adrenal glands. In this multicentric study, data was collected from enrolled centers. Forty-one patients who underwent surgery for suspected adrenal metastases were evaluated retrospectively. The following data types were collected: demographic, primary tumor, maximum standardized uptake value of adrenal mass (a-SUVx) and detectability in computed tomography and/or magnetic resonance imaging, and specimen size and histopathology. Six patients were excluded due to unavailability of PET-CT reports and 4 for being primary adrenal malignancy. The rest were divided into 2 groups (metastatic: n = 17, 55\% and nonmetastatic: n = 14, 45\%) according to histopathology reports. There was no statistical difference between the analyzed values, except the a-SUVx (P < .05). The a-SUVx cutoff value was defined as 5.50 by receiver operating characteristic curves and compared with literature. There was no statistical difference when each group was divided as low and high (P > .05). It was found that PET-CT was able to discriminate metastatic lesions from primary benign lesions (P = .022). PET-CT can discriminate primary benign lesions and metastatic lesions by cutoff 5.5 value for a-SUVx.Item Comparison of effects of energy based devices on quality of life after sutureless thyroidectomy(LIPPINCOTT WILLIAMS \& WILKINS, 2022-01-01) Arikan, Akif Enes; Ozyegin, Mustafa AtesObjective: In current literature, no studies evaluated effect of energy-based vessel-sealing-devices on quality of life after sutureless total thyroidectomies. This study aimed to identify any potential differences between two energy-based vessel-sealing-devices (Harmonic Focus, Ligasure LF1212) in patients with benign thyroid disorders who underwent sutureless total thyroidectomy. Materials and methods: Differences in quality of life of patients were evaluated using data obtained by Thy-PRO-39-Tr questionnaire prior to and four-week after surgery. Total and domain-based alterations in quality of life were compared between groups according to energy-based vessel-sealing-devices type (Group L, Group H). Additionally, data including demographics, height, weight, body mass index, neck circumference, sternomental distance were collected. Results: Of 1032 patients, 200 were eligible for study, at the end 193 were analysed. There were no differences between groups in terms of age, sex, body mass index, tobacco use. Analysis did not reveal any differences in overall quality of life between groups (P = .42). However, in ``eye symptoms{''} (P < .001) and ``cognitive functions{''} (P = .002) domains, Harmonic provided statistically improved quality of life. Effect on cognitive function was greater in patients of advanced age. Conclusions: Especially in elderly patients with worsening eye conditions and cognitive functions, use of Harmonic may enhance patients' outcome by increasing quality of life in addition to optimizing surgical outcome when compared to Ligasure.Item Robotic nipple sparing mastectomy through a single incision: Advantages of starting with posterior dissection(TURKISH SURGICAL ASSOC, 2020-01-01) Uras, Cihan; Arikan, Akif Enes; Kara, Halil; Dulgeroglu, Onur; Avsar, YakupObjective: Loss of breast, which is an important body marking of women, causes a huge decrease in quality of life (QoL) after treatment. In order to overcome this morbidity and increase QoL, nipple sparing mastectomy (NSM) has been developed. Even though the demand for better cosmetic results has yielded endoscopic nipple sparing mastectomy, limitations like unsuitable optical window and limited manual control of rigid-tip instruments, and struggling to keep dissection space have led robotic nipple sparing mastectomy (rNSM) to be developed. Material and Methods: Records of three patients who underwent to rNSM for invasive breast carcinoma with DaVinci Xi (Intuitive Surgical, Sunnyvale, CA) in affiliated hospitals of Acibadem Mehmet Ali Aydinlar University, Research Institute of Senology in 2018 were investigated retrospectively. In all breasts (n= 4), dissection was started from the posterior side of breast. Results: In the unit, 738 breast cancer patients underwent surgery between 2018 and 2019 with an NSM ratio of 31.4\% (n= 232). Of these patients, three underwent rNSM with DaVinci Xi robotic system. The operation was performed on the left breast in one patient, right in one, and bilateral in one patient. Only in patient \#2, who was a neoadjuvant chemotherapy recipient, seroma was observed six weeks after surgery (3 weeks after removal of drains) and spontaneously resolved in 4 weeks. No other complication was seen in all patients. In the follow-up period of median 21 months, no loco-regional recurrence or distant metastasis was seen. Conclusion: A single incision robotic mastectomy can be performed easily and safely when the dissection starts from the pre-pectoral plane rather than the subcutaneous plane.Item Role of Sentinel Lymph Node Biopsy During Contralateral Prophylactic Mastectomy(ISTANBUL TRAINING \& RESEARCH HOSPITAL, 2020-01-01) Kara, Halil; Arikan, Akif Enes; Dulgeroglu, Onur; Uras, CihanIntroduction: Contralateral prophylactic mastectomy (CPM) is the removal of the opposite breast with the aim of risk reduction in cases of unilateral breast carcinoma. Routine use of sentinel lymph node biopsy (SLNB) at the time of CPM is controversial due to low occult breast cancer risk. This study aims to determine the rate of occult breast carcinoma and to evaluate whether SLNB should be performed during CPM. Methods: Ninety-four patients who underwent CPM between 2009 and 2018 were evaluated retrospectively. Occult breast carcinoma detection rate and approach to axilla were evaluated. Results: Occult invasive breast carcinoma was detected in three patients (3.2\%): two invasive ductal carcinoma and one multifocal invasive lobular carcinoma. Axillary staging was performed in second session. SLNB was performed in two patients and a micro-metastasis in one of four sentinel lymph nodes (SLN) was detected in one patient. Axillary lymph node dissection was performed in one patient in whom SLN was not detected. Conclusion: SLNB can be performed in patients with suspicious lesion in the absence of biopsy or in patients with high-risk of occult breast cancer (postmenopausal, high Gail score, lobular histology, multi-centric tumor, ipsilateral high-risk lesion)Item Management of Mechanical Problems of Totally Implantable Venous Catheters(MARMARA UNIV, INST HEALTH SCIENCES, 2020-01-01) Kara, Halil; Arikan, Akif Enes; Dulgeroglu, Onur; Uras, CihanObjective: Although the most common complications of totally implantable venous catheters(TIVC) are infection and thrombosis, mechanical complications can also affect the treatment and cause catheter removal. This study aimed to investigate mechanical complications of TIVC and prevention methods. Methods: Data of 983 procedures in 961patients who underwent TIVC implantation between 2010 and 2019 in AcibademMaslak, Bakirkoy, and Atakent Hospitals were retrospectively analyzed for mechanical complications. Results: Mechanical complications were encountered in 33(3.3\%) cases: 12(1.2\%) were detachment of TIVC, 8(0.8\%) occlusions, 5(0.5\%) pneumothorax, 1(0.1\%) hemothorax, 1(0.1\%) malposition, 1(0.1\%) extravasation, 2(0.2\%) TIVC rotation, 3(0.3\%) skin necrosis and extrusions. Conclusion: The catheter tip should be placed in distal superior vena cava, reservoir pocket must be sufficient in size, reservoir should be fixed to pectoral muscle or fascia at least two points with nonabsorbable sutures. Subcutaneous fatty tissue resection from reservoir pocket should be performed in obese patients. The nature of the withdrawn blood form Seldinger needle should be checked visually whether venous or not. Risk of pneumothorax and detachment can be reduced by inserting the catheter from 1/3 outer part of the clavicle during percutaneous technique. While complication rate can be reduced by peroperative fluoroscopy use, control X-ray should be taken in symptomatic patients, not routinely. Malposition can be seen in the peroperative period and can usually be corrected by good manipulation. Percutaneous transcatheter retrieval in addition to surgery is the gold standard treatment for detachment of TIVC. The most important factors in preventing complications are surgical experience and good care.